Hitachi RAF-35RPA RAF35RPA User Manual

Product codes
RAF35RPA
Page of 706
 
13-3 
 
 
– 
Please refer to the installation manuals for wire 
connection to the terminals of the units. The cabling 
must meet the standards of electrical installation 
– 
There is a AC voltage of 230V between the L and N 
terminals. Therefore, before servicing, be sure to 
remove the plug from the AC outlet or switch off the 
main switch. 
13.2.2 ELECTRICAL WIRING FOR OUTDOOR UNIT 
Please remove the side cover for wire connection 
WARNING: 
– 
If you cannot attach the side cover due to the 
connecting cord, press the connecting cord in direction 
to the front panel to fix it. 
– 
Be sure that the hooks of the side cover are fixed in 
certainly. Otherwise water leakage may occur and this 
causes short circuit of faults.. 
– 
The connecting cord should not touch the service 
valve or pipes. (It becomes high temperature during 
heating operation) 
Checking for electric source and the voltage range 
Before installation, the power source must be checked 
and the necessary wiring work must be completed. To 
ensure poper wiring capacity, refer to the list of wire 
gauges below for the lead-in from the pole transformer and 
for the wiring from a switch board of a fuse box to the main 
switch and outdoor unit in consideration o fthe locked rotor 
current. 
IMPORTANT 
Cable length 
Wire cross section 
Up to 6m 
1.5mm
2
 
Up to 15m 
2.5mm
2
 
Up to 25m 
4.0 mm
2
 
 
 
(Earth wire and grounding rod are not supplied. Please 
use optional items) 
CAUTION: 
– 
Arrange the power cord so they do not touch the 
service valves 
 
• 
Applicable models : RAM-36NP2A / 53NP2A 
 
• 
Applicable model: RAM-53NP3A / 68NP3A / 
130NP6A 
 
• 
Applicable model : RAM-70NP4A 
 
Connect the 
earth cord 
After remove 
the screw 
and cover, 
put the 
connecting 
cords and fix 
the cover 
with screws 
Connect 
the cord 
Connect the 
earth cord 
After remove 
the screw and 
cover, put the 
connecting 
cords and fix 
the cover with 
screws 
Bind connecting cords to 
make them fit between the 
convex sections 
Earth line 
Type of grounding rod: SP-EB-2 
Length: 900mm 
(Optional) 
After 
remove the 
screw and 
cover, put 
the 
connecting 
cords and 
fix the cover