14.5.2  NO OPERATION OR ABNORMAL OPERATION (RAC-18/25/35WSA, RAC-25/35/50WXA, RAC-
50/60/70WPA, RAC-50FPA, RAC-50FXA, RAC-50/60/70DPA 
 
Is AC220~240V being generated at terminals L-N?
Is the 25A fuse normal?
If the 25A Fuse has blown, other 
parts may also be broken. (Mainly, 
varistor, diode stack, IPM, smoothing 
capacitor and etc).
Replace outdoor 
P.W.Bs.
Check reactor wire 
connection correctly or 
replace reactor.
Is DC 320-360V being 
generated ? Refer lable on top 
of electrical cover for 
checking point.
Check the connection of 
reactor wires.
Replace outdoor 
P.W.Bs.
Is the power circuit normal? 
Refer circuit diagram.
Has the 3.15A fuse blown?
Replace outdoor 
P.W.B Main. (Power 
circuit abnormal) 
Check outdoor fan motor. 
(Please refer page  for 
outdoor fan motor or label 
on top of electrical cover for 
detail)
Replace outdoor 
P.W.B Main. (Power 
circuit or fan motor 
drive circuit abnormal)
Replace outdoor P.W.B 
Main and outdoor fan 
motor. (Fan motor or 
fan motor driver circuit 
abnormal)
Supply again power supply 
and ON the unit using 
remote control.
Replace outdoor 
P.W.B Main. (Micro 
computer or LED 
abnormal)
Yes
No
No
Yes
Normal
No
Yes
Yes
Outdoor 
fan motor 
normal
Outdoor fan motor 
abnormal
LD301 not lit. Power 
circuit is OK.
No
Yes
Is LD301 lamp light?
No
Confirm blinking times 
of LD301.
Yes
LD301    13 times blinking
EEPROM data reading 
error
Replace outdoor P.W.B 
Main. (Micro computer 
or EEPROM abnormal)
Yes
No
LD301    9 times blinking
Communication error
Check connecting cable connection. 
(Half insert, connect using small 
diameter cable and etc).
Check and repair the 
connection of 
connecting  cable.
Yes
Abnormal
No
Confirm indoor timer lamp blinks.
Normal
Check indoor electrical 
assembly. (Check 
temperature fuse for 
terminal board)
3 times 
blinking
Is the JW001 and JW002 connected? 
(Forget to disconnect after  do self 
check)
Normal
Disconnect JW001 and 
JW002, then check 
again.
Connected
Replace outdoor P.W.B 
Main. (Communication 
circuit abnormal)
Normal
No