Compressor fail to start. 
Check wire continuity and 
disconnection connector.
Compressor 
wire connector 
unplug, check 
wire continuity.
Fixing the 
abnormal place.
Conduct self check.
RL3 or Q601 might be broken
Based on [self-
check], replace 
the defect part.
Outdoor fan motor abnormal due to:
1.
Fan stop due to strong wind.
2.
Something blocking the fan.
3.
Fan motor broken.
4.
Fan motor driver circuit broken.
Replace outdoor 
P.W.Bs. (RL3 or Q601 
abnormal)
Remove the 
unnecessary 
thing. If 
found fan is 
abnormal, 
replace the 
fan motor.
Wait till wind become weak then 
restart again the unit.
Check whether fan 
motor connector 
disconnect.
Check if thermistor wire disconnector 
or short.
Does the wind strong? 
Reconfirm again after 
restart the unit.
Is there is an 
abnormalities with the 
outdoor fan motor.
Not a defect of 
fan motor or 
outdoor electrical 
assembly.
Replace outdoor P.W.B 
Main. (Fan motor driver 
circuit abnormal)
Yes
No
Yes
Yes
No
Abnormal
Abnormal
LD301  4 time  blinking.
Switching failure
LD301  2 times  blinking.
Peak current cut
LD301  14 times  blinking.
ACT voltage abnormal
Normal
LD301  12 times  blinking.
Fan lock stop
No
Insert connector.
Normal
Fan stop due to strong 
wind
LD301  11 times  blinking
No
Continues run
Stop
Replace fan 
motor.
Fan motor 
abnormal
LD301  3 time  blinking.
Abnormal low speed 
rotation
Operation stop due to 
abnormalities found in 
controlling the compressor. 
Maybe the load is very heavy.
Yes
Operation stop due to 
compressor current 
abnormal. Maybe the load is 
very heavy.
No
Yes
Yes
Abnormal
Check whether 
there are 
unnecessary 
thing blocking 
the fan motor.
Abnormal
Normal
Fan motor 
normal