Hitachi RAF-35RPA RAF35RPA User Manual

Product codes
RAF35RPA
Page of 706
 
14-37 
 
 
 
 
 
Communication error 
Communication between indoor and 
outdoor is interrupted 
①C-D cable wrongly connected 
②Open connection on the C-D cable. 
③Interface circuit of indoor/outdoor unit. 
9 Times 
 
 
 
 
Abnormal power voltage 
Abnormal power source is detected. 
①Abnormal power source 
②Cable is wrongly connected 
③Main P.W.B. 
10 Times 
 
 
 
 
Fan lock error 
Outdoor fan actual rpm could not 
reach as per instructed. 
①Outdoor fan motor 
②Fan motor circuit. 
12 Times 
 
 
 
 
EEPROM read error 
Microcomputer cannot read the data 
in EEPROM. 
①Main P.W.B.  
13 Times 
 
 
 
 
ACTIVE CONVERTER 
defective 
Over Voltage is detected by System 
Power Module 
①System Power Module.  
14 Times 
Example of blinking (5 times) 
 
 
 
 
 
Abnormal Thermistor 
Thermistor is opened or shorted. 
Refer to the table below 
①Thermistor ②Connection of Thermistor 
is faulty ③Thermistor Circuit 
Lit 
1~11 
Times 
Blinking time 
Abnormal Thermistor 
1 Time 
Overheat Thermistor 
2 Times 
Defrost Thermistor 
3 Times 
Outdoor Temperature Thermistor 
 
 
 
 
Communication error 
Communication between indoor and 
outdoor is interrupted 
①C-D cable wrongly connected 
②Open connection on the C-D cable. 
③Interface circuit of indoor/outdoor unit. 
1 Time