b)  When installing on the room air-conditioner 
In case that it cannot be installed to the wall due 
to the space or material problem, install the RAC 
adaptor with the two-sided tape  (accessory) on 
the room air-conditioner. 
i) 
Confirm if the piping cover of the unit can be 
removed when performing the service 
maintenance, and then fix the RAC adaptor in 
the side of room air-conditioner with two-
sided tape. (Available at the right as well as 
left side) 
ii) 
Clean the surface to be installed with a dry 
cloth. 
 
NOTE: 
– 
Consider the following points since  the adhesiveness 
changes according to the environmental conditions 
(temperature, humidity etc) 
– 
The adhesiveness is decreased when there is humidity 
or oil. 
– 
Warm the adhesive part and installation place of the 
two-sided tape to avoid the decrease of the 
adhesiveness in case the ambient temperature is low. 
– 
DO NOT touch the adhesive part by fingers nor re-
attach it many times. The adhesiveness has 
decreased and the RAC adaptor may fall off. 
– 
DO NOT apply any force within 24 hours after 
installation. 
15.3.3.  ELECTRICAL WIRING 
 
System configuration 
 
CAUTION: 
– 
Turn OFF the power supply of the room air-conditioner 
of the central control device when performing the 
wiring work 
– 
DO NOT run all the H-LINK cable or power supply 
cable along the other signal cable, or malfunction may 
occur due to the noise, etc. If it is required to run along 
the other transmission cable, separate the cable more 
than 30cm, or run the cable through the metal tube 
and earth the tube. 
– 
Follow local codes and regulations when performing 
electrical wiring and earth wiring. 
– 
Transmissions cable used in H-LINK shall be 2 cores 
cable (0.7mm
2
  to 1.25mm
2
  for model: VCTF, VCT, 
CVV, MVVX, CVVX, VVR, VVF) or 2 cores twisted pair 
cable (model: KPEV, KPEV-Spec). Total length of 
cable shall be below 1000mm. 
– 
DO NOT use wire with more than 3 cores. 
 
Internal components and Wiring connections 
Check the contents and the number of the accessories in 
the packing. 
• 
Access 
Open the cover by removing the ① and ② screws. 
 
• 
Wiring Connection 
Connection with Room Air-Conditioner 
i) 
Remove the front cover of the room air-
conditioner and the cover of electrical box. 
ii) 
The cable attached with the connector of the 
RAC adaptor shall be connected with the 
connector of indoor PCB 
 
An example of 
installation at the right 
side 
RAC 
adaptor 
Cover 
40mm 
Keep distance of 10mm 
Central Station web  Central Station  
Indoor unit  
Indoor unit  
RAC 
adaptor 
Outdoor 
unit 
H-LINK 
Room Air- conditioner 
Outdoor unit  
H-LINK  
RAC 
adaptor 
Indoor 
unit 
Indoor 
unit 
Outdoor 
unit 
Outdoor 
unit 
HITACHI 
PSC-6RAD 
Electrical Box 
RAC Adaptor 
Remote Control