Copper Connectivity Solutions – Category 6
Copper Cable Solutions
Category 6 Copper Cable
Impedance
Attenuation Return Loss
Attenuation-To-NExT Ratio
(Ohms)
(dB/100m) (dB) Pair-To-Pair PowerSum
Freq
(dB/100m) (dB/100m)
(MHz)
Input
Characteristic
Typical Spec
Typical Spec
Typical Spec Typical Spec
Typical
Typical
1
100 ± 5
100 ± 5
1.6
2.0
20.3
20.0 94.8
72.3 88.0 70.3
4
100 ± 5
100 ± 3
3.2
3.8
35.2
23.0 86.7
61.5 79.9 59.5
8
100 ± 5
100 ± 3
4.6
5.3
41.1
24.5 80.0
55.4 73.5 53.4
10
100 ± 5
100 ± 3
5.2
6.0
40.2
25.0 80.1
53.3 72.0 51.3
16
100 ± 5
100 ± 2
6.7
7.6
41.0
25.0 73.8
48.7 65.9 46.7
20
100 ± 5
100 ± 2
7.5
8.5
41.1
25.0 70.0
46.3 63.0 44.3
25
100 ± 5
100 ± 2
8.4
9.5
42.2
24.3 70.4
43.8 63.6 41.8
31.25
100 ± 5
100 ± 2
9.5
10.7
39.5
23.6 64.8
41.2 58.2 39.2
62.5
100 ± 5
100 ± 2
13.9 15.4
40.6
21.5 56.5
32.0 49.7 30.0
100
100 ± 5
100 ± 2
18.3 19.8
36.9
20.1 50.2
24.5 43.2 22.5
155
100 ± 5
100 ± 2
23.5 25.2
38.9
18.8 42.4
16.3 35.0 14.3
200
100 ± 5
100 ± 2
27.3 29.0
35.5
18.0 36.8
10.8 29.6 8.8
250
100 ± 5
100 ± 2
31.3 32.8
36.0
17.3 30.1
5.5 23.8 3.5
300
100 ± 5
100 ± 2
34.9
35.4
26.2
18.8
350
100 ± 5
100 ± 2
38.4
32.5
22.3
15.1
400
100 ± 5
100 ± 2
41.8
33.0
17.3
10.0
550
100 ± 8
100 ± 2
50.6
28.9
5.5
-2.7
NExT
ELFExT
Freq
Pair-To-Pair
PowerSum Pair-To-Pair PowerSum
(MHz)
(dB/100m)
(dB/100m)
(dB/100m) (dB/100m)
Typical
Spec
Typical
Spec Typical
Spec Typical
Spec
1
96.4
74.3
89.6
72.3
92.2 67.8 84.8
64.8
4
89.9
65.3
83.1
63.3
83.3 55.8 74.2
52.8
8
84.6
60.8
78.1
58.8
77.9 49.7 69.4
46.7
10
85.3
59.3
77.2
57.3
74.8 47.8 66.9
44.8
16
80.5
56.2
72.6
54.2
70.2 43.7 62.6
40.7
20
77.5
54.8
70.5
52.8
67.9 41.8 60.2
38.8
25
78.8
53.3
72.0
51.3
66.1 39.8 58.3
36.8
31.25
74.3
51.9
67.7
49.9
63.7 37.9 55.9
34.9
62.5
70.4
47.4
63.6
45.4
58.4 31.9 50.5
28.9
100
68.5
44.3
61.5
42.3
54.9 27.8 46.6
24.8
155
65.9
41.4
58.5
39.4
49.2 24.0 41.8
21.0
200
64.1
39.8
56.9
37.8
45.5 21.8 38.1
18.8
250
61.4
38.3
55.1
36.3
43.6 19.8 35.0
16.8
300
61.1
53.7
38.9
30.4
350
60.7
53.5
34.2
26.3
400
59.1
51.8
3.0
22.5
550
56.1
47.9
19.2
10.8
NOTE: The above listed discrete frequency electrical performance values are provided for engineering information only. Actual compliance
testing is based on swept frequency measurements. The spec values are based on TIA/EIA 568-B.2-1 specifications.
testing is based on swept frequency measurements. The spec values are based on TIA/EIA 568-B.2-1 specifications.
Specifications
ELECTRICAL CHARACTERISTICS
Conductor DC resistance (maximum):
Conductor DC resistance (maximum):
28.6
Ω/1000 feet (9.38Ω/100 meters) @20°C
DC resistance unbalance (maximum):
2%
Mutual capacitance (maximum):
17 pF/foot (5.6nF/100 meters)
Operating temperature (maximum):
75°C
Operating voltage (maximum):
300VDC
Worst case cable skew:
25 nS/100 meters @100MHz
Nominal velocity of propagation:
75% @100MHz
Ordering information follows on the next page