Borri B500 10 kVA B500-100-B User Manual

Product codes
B500-100-B
Page of 4
BORRI B500 
|
EVO
2
3
w w w . b o r r i . c o . u k
External Battery Connector
Input Breaker Switch, with
dual input standard on EVO
Intelligent Card Slot
USB, EPO, RS232 Connectors 
and Alarm Relay
B500 EVO 
|
Features
The 10kVA & 20kVA B500 EVO can have either a three phase or
single phase input applied to the UPS, the decision doesn't have
to be made until the point of installation and can then be
changed should, an electrical supply need to be upgraded or
electrical loads have to be balanced.
The batteries can also be replaced with only front access meaning
other equipment can be located directly adjacent to the UPS.
Future Expansion or Redundancy
To future proof the investment in a B500 UPS, up to four additional units can be
connected in parallel. The B500 is genuinely "easy parallel", all equipment needed for
parallel operation is included within the initial purchase of the first unit making it very
simple to provide further capacity or redundancy.
UPS Management
The B500 features an Intelligent Slot for the
installation of programmable relay alarm cards,
SNMP communication or RS485 MODBUS
connection. In addition,  the B500 has
USB and RS232 communication for
connection to a local server,
a programmable dry relay contact, an
EPO connection facility and a
connection for interlocking with an
external bypass switch as standard.
The product comes complete with a
free download of user friendly
monitoring and shut-down software
suitable for the majority of operating
systems.
Generator Friendly
The rectifier stage of the B500 has been
designed to provide a unity input power
factor and Input Total Harmonic
Distortion (THDi) of 5% maximum. 
This makes the UPS extremely generator
friendly, increases efficiency and negates the
need to oversize input cables and switchgear.
Smart LCD Display
The LCD display allows users to interrogate
the UPS for current status, history logs, load
reading and UPS settings.
On-line Double Conversion
The B500 range was developed around the highest level of protection
(On-line Double Conversion), this means that the output is VFI (Voltage
& Frequency Independent) allowing the critical load power to be
constantly maintained by the UPS inverter, this in turn means the load
does not see any mains borne interferences and delivers a zero-break
transition from utility power to battery.
More Power / Smaller Footprint
Ideal for all critical IT Environments where space is at a premium.
The tower based UPS delivers up to 25% more usable power than
other manufacturers thanks to a 0.9 Output Power Factor.  The B500
also comes complete with internal batteries as standard, throughout
the range, eliminating the need for external battery cabinets on
standard run times, minimising the footprint and therefore maximising
floor space for other equipment.
Highest Protection
The B500 includes a static and internal manual bypass switch as
standard, with zero transfer time between inverter and bypass. 
The wide input voltage window reduces the amount of time spent on
switching to or running on battery power, thereby increasing battery
service life, UPS efficiency and reliability. A powerful internal charger
enables backup times of up to 8 hours with a 6 hour recover time.
Frequency Converter
All of the B500 range can be used as a frequency converter.
On-Line Double Conversion
Topology
High Efficiency Mode Function
up to 98%
Wide Input Voltage Window
Selectable Output Voltage 
Frequency Converter Feature
EPO Connection
Smart-slot
Plug n Play Parallel kits
Standard
Internal Manual Bypass
Intelligent Shutdown and
monitoring software
B500 Main Features
Incorporating Borri’s On-line Double Conversion Technology, the new B500 6kVA and 10kVA and
B500 EVO 10kVA and 20kVA series are extremely low maintenance and have been designed as a
true ‘easy parallel’ UPS solution.
BORRI B500 BROCHURE  12/10/11  14:17  Page 3