Borri B3X1000i B3X1000RMI2U Leaflet

Product codes
B3X1000RMI2U
Page of 2
BORRI Ltd
|
Systems House
|
Rotherside Road
|
Eckington
|
Sheffield 
|
S21 4HL
Tel: +44 (0)1246 431431
|
Fax: +44 (0)1246 431444
Email:
sales@borri.co.uk
|
Web:
www.borri.co.uk
MODELS
B3X1000i
B3X1500i
B3X2000i
B3X3000i
INPUT
Cold Start
Yes, default frequency=50Hz
Input Voltage Window
176VAC-288VAC
Phase
Single phase
Transfer Voltage Range - Normal 
220/230/240VAC
Input Frequency Range - Normal
45-55Hz / 55-65Hz (±0.1 Hz)
OUTPUT
Power
Power(kVA) 
1.0
1.5
2.0
3.0
Power(kW) 
0.9
1.4
1.8
2.7
Power Factor
0.9
0.9
0.9
0.9 
Output Voltage
Waveform
Pure Sine Wave
Nominal voltage
220VAC/230VAC/240VAC
Voltage regulation (Battery Mode)
± 5 %
Voltage distortion (Typical)
< 10% THD, linear load        
< 12% THD, non-linear load        
Output Frequency
Synchronization range
45-55Hz / 55-65Hz
Battery mode
50/60±0.1 Hz
Transfer Time
Line mode to battery mode (Normal mode)
2 ~ 6 mS
Line mode to battery mode (Generator mode)
13 mS (max)
Full Load Efficiency
Normal Line mode with battery full charged
>97%
Buck mode with battery fully charged
>95%
Boost mode with battery fully charged
>92%
Battery mode @ 12VDC/Battery
>82%
Overload Capability (Line Mode)
110% +/-10% : 3 min 
150% +/-10% : 0.2 s
Overload Capability (Battery Mode)
>110% ±10% :  30 s 
>120% ±10% :  0.1 s 
Crest Ratio
3:1
Parallel
1+1 for capacity and redundancy
BATTERY
Rating/Type
12VDC/7Ah
12VDC/9Ah
12VDC/7Ah
12VDC/9Ah
Quantity
3
3
6
6
DC Voltage
36VDC
36VDC
72VDC
72VDC
Back-up Time (full load)
4.5 minutes
3  minutes
4.5 minutes
3  minutes
Back-up Time (half load)
10 minutes
7 minutes
10 minutes
7 minutes
Charger
-Charging current (max)
1.5A
-Charging time
3h charge to 90%
FEATURES
EPO Function
YES
Load Segments Control 
YES
Swappable LCD Direction
YES
Rack-Tower 2-in-1 Design
YES
Extended Run Time
YES
Easy Battery Replacement
YES
RS232
Standard, supports WinPower Software
USB
Standard, supports WinPower Software
Intelligent Slot
NMC / AS400 Card
Network Transient Protection
RJ45
MECHANICAL
WxDxH (mm)-UPS
438x430x86.5
438x430x86.5
438x600x86.5
438x600x86.5
Net Weight-UPS
16/22.1kg
16/22.1kg
29.5/41.1kg
29.5/41.1kg
Operating Altitude
0-1500 meters, @ 0~40 °C 1501-3000 meters, @ 0~35 °C
Operating Temperature Range
UPS: 0°C ~ 40 °C - BATTERIES: 20°C ~ 25 °C
Relative Humidity
0 ~ 95% (Non condensing)
Audible Noise (Line mode)
<40dB @ 1meter 
<45dB @ 1meter 
AC Outlets
IEC C13 x8
IEC C13 x8
IEC C13 x8
IEC C13 x8 + IEC C19 x1
REGULATIONS
Conduction Emission
IEC 62040-2 
CS
IEC61000-4-6
Radiation Emission
IEC 62040-2
RS
IEC 61000-4-3 
ESD
IEC 61000-4-2 
EFT
IEC 61000-4-4 
Surge
IEC 61000-4-5 
Safety
EN 62040-1-1
BORRI
|
B300 ROTATION
Technical Specification
Rear view of B3X1000i/1500i
Rear view of B3X2000i
Rear view of B3X3000i
LINE INTERACTIVE
BORRI 
|
B300 ROTATION
1000VA, 1500VA, 2000VA & 3000VA
Please note that information contained within this document has been prepared by and is the sole responsibility of Borri Ltd