Dimensions / Weight
Dimension notes
Floorstand Width 306 mm with tilt protection; depth measured excludes handles on redundant PSU. Rack depth 
excludes handles of redundant PSU and rack front.
Mounting Depth Rack
543 mm
Height Unit Rack
4 U
Weight
Rack: 12.5kg - 20kg; Tower: 15kg - 23 kg
Weight notes
Actual weight may vary depending on configuration
Rack integration kit
Rack integration kit can be ordered as option
Environmental
Operating ambient temperature
10 - 35 °C
Operating relative humidity
10 - 85 % (non condensing)
Operating environment
FTS 04230 – Guideline for Data Center (installation specification)
Operating environment Link
http://docs.ts.fujitsu.com/dl.aspx?id=e4813edf-4a27-461a-8184-983092c12dbe
Sound pressure (LpAm)
SATA: 25 dB(A) idle mode/ 25 dB(A) operation mode; SAS: 31 dB(A) idle mode/ 34 dB(A) operation mode
Sound power (LWAd; 1B = 10dB)
SATA: 4.2 B idle mode/  4.2
 B operation mode ; SAS: 4.8 B idle mode/ 5.2 B operation mode 
Noise notes
Noise emissions and operation modes depend on system configuration.
Electrical values
Power supply configuration
1x standard, 1x hot-plug or 2x redundant hot-plug
Max. output of single power supply
450 W
Standard power supply output
300 W (90 % efficiency)
Hot-plug power supply output
450 W (94 % efficiency, 80 PLUS platinum)
Hot-plug power supply redundancy
Yes
Rated voltage range
100 V - 240 V
Rated frequency range
47 Hz - 63 Hz
Rated current max.
6 A / 3 A  (100 V / 240 V) 
Active power (min. configuration)
23 W
Active power (max. configuration)
203 W
Active power note
To estimate the power consumption of different configurations use the Power Calculator of the System Architect: http://
configurator.ts.fujitsu.com/public/
Apparent power (max. configuration)
247 VA
Heat emission
730.8 kJ/h (692.7 BTU/h)
Power Supply Notes
The active power and apparent power values may change according to configuration.
Compliance
Global
CB
RoHS (Restriction of hazardous substances)
WEEE (Waste electrical and electronical equipment)
Germany
GS
Europe
CE Class A *
USA/Canada
CSA us
ULc/us
FCC Class A
Japan
VCCI
Russia
GOST-R
South Korea
KC
China
CCC
Australia/New Zealand
C-Tick
Taiwan
BSMI
Compliance link
http://globalsp.ts.fujitsu.com/sites/certificates 
Compliance notes
* Warning:
This is a class A product. In a domestic environment this product may cause radio interference in which case the user 