DKTCOMEGA Freja T0B 52260 User Manual

Product codes
52260
Page of 24
push-on passive tv/fm/data filters
Product information
The “push-on” passive multimedia filters are available in various configurations. These satisfy the  
demands made for passive filtering of TV, FM and DATA signals in modern CATV home networks.
17
Type
POF 4-4
POF 7-7
POF 1-4
POF 1-10
Item no.
42102
42103
42100
42101
Version
Standard 
Standard 
Diplex 
Diplex
DATA
Frequency forward (MHz)
118-1000
118-1000
118-1000
118-1000
Frequency reverse (MHz)
5-65
5-65
5-65
5-65
Insertion loss forward (dB)
4,0 (±0,5)
7,0 (±1,0)
4,0 (±0,5)
10,0 (±1,0)
Insertion loss reverse (dB)
4,0 (±0,5)
7,0 (±1,0)
0,6 (±0,5)
  0,6 (±0,5)
Return loss* EN50083-4
Cat. B
Cat. B
Cat. B
Cat. B
Isolation to TV/DATA (dB)
 5-65 MHz
50
50
50 
50 
Isolation to TV/DATA (dB)
 118-470 MHz
30
20
25 
27 
Isolation to TV/DATA (dB)
 470-1000 MHz
20
17
23 
24 
Connector
F-Female
F-Female
F-Female
F-Female
TV
Frequency range (MHz)
87-1000
87-1000
118-1000
118-1000
Insertion loss (dB)
4,0 (±0,5)
2,0 (±0,5)
4,0 (±0,5)
1,6 (±0,5)
Isolation TV OUT / TV IN (dB) 
5-65 MHz
35
35 (5-65)
50 
50 
Connector
IEC-Male
IEC-Male
IEC-Male
IEC-Male
FM
Frequency range (MHz)
87,5-108
87,5-108
87,5-108
87,5-108
Insertion loss (dB)
0,6 (±0,5)
0,6 (±0,5)
0,6 (±0,5)
0,6 (±0,5)
Isolation FM OUT / FM IN (dB) 
5-65 MHz
30
30
30
30 
Connector
IEC-Female
IEC-Female
IEC-Female
IEC-Female
Push-on filters
These multimedia push-on passive filters are available in standard 
and diplex versions. Standard versions have a higher attenuation in 
the return path and are suited to home applications where extra 
loss in the data signal is tolerable. Diplex versions are designed 
with extremely low return path attenuation and for separation of 
TV, FM and satellite intermediate frequency bands.
Freja Push-on filters
The Freja push-on passive filter satisfies the  
demands made by modern CATV household    
installations where passive filtering of TV, FM and 
DATA signals is required.
Type
Freja POF 1-4
Item no.
42108
Version
Diplex
DATA
Frequency forward (MHz)
118-1000
Frequency reverse (MHz)
5-65
Insertion loss forward (dB)
4,0 (±0,5)
Insertion loss reverse (dB)
0,5 (±0,5)
Return loss* EN50083-4
Cat. B
Isolation to TV/DATA (dB) 
5-65 MHz
45
Isolation to TV/DATA (dB) 
118-470 MHz
25
Isolation to TV/DATA (dB) 
470-1000 MHz
23
Connector
F-Female
TV
Frequency range (MHz)
118-1000
Insertion loss IN-TV (dB)
4,0 (±0,5)
Isolation TV OUT / TV IN (dB) 
5-65 MHz
35
Connector
IEC-Male
FM
Frequency range (MHz)
87,5-108
Insertion loss IN-FM (dB)
0,6 (±0,5)
Connector
IEC-Female
Dimension
 (H 68 x W 50 x D 24 mm)
According to CENELEC: 
 
A: 5-40 MHz ≥ 22 dB, min. 14 dB @ 40-1750 MHz ÷ 1,5/oct. 
B: 5-40 MHz ≥ 18 dB, min. 10 dB @ 40-1750 MHz ÷ 1,5/oct. 
C: 5-40 MHz ≥ 14 dB, min. 10 dB @ 40-1750 MHz ÷ 1,5/oct. 
D: 5-1750 MHz ≥ 10 dB
 
Reduced performance can be expected in the 862-1000 MHz range.
Dimension
 (H 62 x W 84 x D 25 mm)