DKTCOMEGA Freja T0B 52260 User Manual

Product codes
52260
Page of 24
Product information
These TV/FM outlets comply with industry standards   
and have focus on screening efficiency and easy,  
 
flexible and stable cable installation. Full program    
with terminated or loop-through, each with specific   
attenuation, to match all type of networks.
Each outlet is available with a front plate and surface  
mounting frame (C), with a front plate only (FP) or without 
any enclosure.
All outlets are assigned colour codes on the IEC constructions, 
in order to identify the type of outlet on the front (See page  
23 for more information regarding these codes).
 
Explanation to “version”: Std. = Standard (no diplex), Dip = 
Diplex filter, TM = Terminated, LT = Loop-through
passive tv
 
/
 
fm outlets
Type *
Item no.
52500
Version
Std, TM
TV
Frequency range
5-68 / 118-1000
Insertion loss IN-TV (dB)
1,0
Return loss** EN50083-4
Cat. C
Isolation to FM (dB)
> 15
Connector
IEC-Male
FM
Frequency range (MHz)
87,5-108
Insertion loss IN-FM (dB)
1,3
Connector
IEC-Female
Type *
T4BX-C
T7BX-C
T10BX-C
T13BX-C
T16BX-C
Item no.
52505
52510
52515
52520
52525
Version
Std, TM
Std, TM
Std, TM
Std, TM
Std, TM
TV
Frequency range (MHz)
5-68 / 118-1000
5-68 / 118-1000
5-68 / 118-1000
5-68 / 118-1000
5-68 / 118-1000
Insertion loss IN-TV (dB)
4,0
7,0
10
13
16
Return loss** EN50083-4
Cat. C
Cat. C
Cat. C
Cat. C
Cat. C
Isolation to OUT (dB)
> 20
> 20
> 30
> 30
> 30
Connector
IEC-Male
IEC-Male
IEC-Male
IEC-Male
IEC-Male
FM
Frequency range (MHz)
87,5-108
87,5-108
87,5-108
87,5-108
87,5-108
Insertion loss IN-FM (dB)
4,5
7,5
10
13
16
Connector
IEC-Female
IEC-Female
IEC-Female
IEC-Female
IEC-Female
IN & OUT
Frequency range (MHz)
5-1000
5-1000
5-1000
5-1000
5-1000
Insertion loss IN-OUT (dB)
3,8
2,8
1,8
0,9
0,9
Return loss** EN50083-4
Cat. C 
Cat. C
Cat. B
Cat. B 
Cat. B
5
Dimension   (H 82 x W 82 x D 30 mm)
Back box only. Faceplate adds 8 mm to depth to overall 38 mm.
Type suffix defines product package:
 
C - complete housing (front and back), example T0BX-C. 
FP - front plate only, example T0BX-FP. 
No suffix - no front or back, example T0BX. 
Each available in minimum order quantity of 10 units.
C
FP
Terminated outlets in star networks  
Loop-through outlets in cascading networks
** 
According to CENELEC 50083: 
 
A: 5-40 MHz ≥ 22 dB, min. 14 dB @ 40-1750 MHz ÷ 1,5/oct. 
B: 5-40 MHz ≥ 18 dB, min. 10 dB @ 40-1750 MHz ÷ 1,5/oct. 
C: 5-40 MHz ≥ 14 dB, min. 10 dB @ 40-1750 MHz ÷ 1,5/oct. 
D: 5-1750 MHz ≥ 10 dB