Belden 2.1m Cat6+ RJ45 C601109007 User Manual

Product codes
C601109007
Page of 3
Storage Temperature Range:
-40°C To +70°C
Installation Temperature Range:
-10°C To +60°C
Operating Temperature Range:
-10°C To +60°C
Max. Recommended Pull Tension:
111.205 N
Min. Bend Radius (Overall Cable):
26.416 mm
Environmental/Mechanical Characteristics:
Test (Method)
TIA 568-C.3
Belden
Thermal Cycling (FOTP-3)
n/a
-40 to 75°C cycling for 7 days
Temperature Life (FOTP-4) 60°C for 4 days
85°C for 7 days
Humidity (FOTP-5)
90-95% at 40°C for 4 days
95% @ 75°C for 7 days
Durability (FOTP-21)
500 cycles
6 x 200 cycles (3 Elevations)
Cable Retention (FOTP-6)
5.0 kg @ 0 deg., 1.94 kg @90 deg. 6.8 kg @ 0 deg., 3.4 kg @ 90 deg.
Flex (FOTP-1)
0.5 kg @ 90° to -90° for 100 cycles 0.9 kg @ 90° to -90° for 100 cycles
Twist (FOTP-36)
1.5 kg for 10 cycles
1.5 kg for 10 cycles
Overall Length Tolerances:
Range
Max. Length Tolerance Min. Length Tolerance
0 - 2m
0.2m
-0.0m
2.1 - 4.9m 0.3m
-0.0m
5 - 40m
0.4m
-0.0m
Over 40m 1.0 percent
-0.0 percent
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
UL Rating:
Riser
Other Standards:
FCC Part 68, Subpart F, IEC 60603-7
EU Directive 2002/95/EC (RoHS):
Yes
EU RoHS Compliance Date (mm/dd/yyyy):
01/01/2006
MII Order #39 (China RoHS):
EUP 50
Telecommunications Standards:
Category 6 - TIA 568.C.2, ISO/IEC 11801:2002 Ed.2
Safety Listing:
ACA, Bi-national Standard Listed
Suitability
Suitability - Indoor:
Yes
Transmission Characteristics (Connectivity)
Optical Connector Performance:
Description
OM1
OM2
OM3
OM4
OS2 / UPC OS2 / APC
Maximum Insertion Loss (dB) 0.5 dB 0.5 dB 0.5 dB 0.15 dB 0.5 dB
0.5 dB
Minimum Reflectance (dB)
-20 dB -20 dB -20 dB -20 dB
-50 dB
- 65 dB
Performance Table 1:
Frequency 
(MHz)
Max. 
Insertion Loss 
TIA* (dB)
Max. 
Insertion Loss
Belden (dB)
Min. 
PSNEXT 
TIA* (dB)
Min 
PSNEXT 
Belden (dB)
Min. 
PSACRF 
TIA* (dB)
Min. 
PSACRF 
Belden (dB)
1.000
2.400
2.000
72.300
73.300
64.800
67.800
4.000
4.500
3.700
63.300
64.300
52.800
55.800
8.000
6.400
5.200
58.800
61.300
46.700
49.700
10.000
7.100
5.900
57.300
59.800
44.800
47.800
16.000
9.100
7.400
54.200
56.600
40.700
43.700
20.000
10.200
8.300
52.800
55.100
38.800
41.800
25.000
11.400
9.300
51.300
53.500
36.800
39.800
31.250
12.800
10.400
49.900
52.000
34.900
37.900
62.500
18.500
14.900
45.400
47.100
28.900
31.900
100.000
23.800
19.000
42.300
43.800
24.800
27.800
200.000
34.800
27.500
37.800
38.900
18.800
21.800
250.000
39.400
31.000
36.300
37.300
16.800
19.800
300.000
34.200
36.100
18.300
Performance Table - Footnote:
100 Meter Cable Specifications - * TIA-EIA-568-C.2 Category 6 Standard -------- PSACRF is formally
PSELFEXT
Performance Table 2:
Frequency (MHz)
Min. 
Return Loss 
TIA* (dB)
Min. 
Return Loss 
Belden (dB)
Min. 
Balanced TCL 
TIA* (dB)
Min. 
Balanced TCL 
Belden (dB)
1.000
20.000
20.000
40.000
40.000
4.000
23.000
23.000
40.000
40.000
 
Page 2 of 3 
07-23-2014
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
C601109007  Cable Assemblies - CAT6+ Modular Cord