Cablecon 99904940 Data Sheet

Page of 1
DATA SHEET 
O:\TestAfd\DATABLAD\Nye\Bieffe cavi\CO 12 B 90 LSF\99904940 F-56-ALM 5.3-8.4\99904940 - Data Sheet 75   Form 041 rev.7.doc 
 
ISO 9001:2000 / ISO 14001 certified
 
 
          
Distributor: 
 
 
Corning Cabelcon ApS, Industriparken 10, DK 4760 Vordingborg 
 
Tel: +45 55 98 55 99  ·  Fax: + 45 55 98 55 04 
 
E-mail: cabelcon@cabelcon.dk   ·   
www.cabelcon.dk
  
Form 041 rev 7 
   
 
 
Item no.   99904940 
Connector type 
 F-56-ALM 5.3/8.4 
 
 
For cable 
 Bieffe Cavi CO 12 B 90 LSF 
  
           
  
      
 
 
 
 
Frequency Range 
0.3 - 3000 MHz   
Impedance
 
(Nom.)
 
75 Ω 
Amp. Rating 
(measured)
 
         Cable data 
 
(calculated) 
         Cable data 
Transfer Impedance 
(CoMeT)
 
2,0 mΩ/m @ 5-30MHz 
 
0,04 mΩ/item @ 5-30MHz 
Shielding Effectiveness
(CoMeT)
   
100 dB @   30-  862MHz 
 
78 dB @ 862-3000MHz 
All tests performed using instruments calibrated in accordance 
to our ISO 9001 certification. 
Further technical specifications and installation instructions can 
be obtained on request.
 
 
 
 
Return Loss 
(IEC 61169-1) 
 
 
 
 
  Insertion Loss Max. 
 
 
(RF Analyzer HP 8714C) 
Better than 
Typical 
 
Better than 
Typical 
0.3 - 500 MHz 
 
-43  dB 
 
-46,8  dB 
  0.3 - 500 MHz 
 
-0,06  dB 
 
-0,01  dB 
500 - 860 MHz 
 
-37  dB 
 
-40,3  dB 
  500 - 860 MHz 
 
-0,07  dB 
 
-0,02  dB 
860 - 1000 MHz 
 
-36  dB 
 
-38,5  dB 
  860 - 1000 MHz  
 
-0,07  dB 
 
-0,02  dB 
1000 - 1750 MHz 
 
-27  dB 
 
-30,4  dB 
  1000 - 1750 MHz 
 
-0,10  dB 
 
-0,05  dB 
1750 - 2150 MHz 
 
-25  dB 
 
-28,5  dB 
  1750 - 2150 MHz 
 
-0,11  dB 
 
-0,06  dB 
2150 - 3000 MHz 
 
-22  dB 
 
-25,5  dB 
  2150 - 3000 MHz 
 
-0,12  dB 
 
-0,07  dB 
           
                
                
             
                
                
           
                
                
             
                
                
 
 
 
 
Temperature 
 
  Intermodulation 
IM3 
IP3-value 
Installing 
  -5° to +50° C 
  3rd Order (@2x100mW) 
 
-125  dBc   
+82  dBm 
Operating 
  -40° to +100° C 
 
 
Storing 
  -40° to +100° C 
  Inner Conductor Resistance 
 
 
  (@ 1 A DC) 
              Cable data 
 
 
 
 
Sealing Test 
 
  Insulation Resistance 
(IEC IP-code) 
        - 
  (@ 500 VDC) 
              Cable data 
 
 
 
 
 
 
  Dielectric Strength 
 
O-rings 
          -    
  DC Test Voltage 
              Cable data 
 
 
 
   
 
Base Material 
 
  Max. Tensile Strength 
 
Body Parts 
Brass CuZn39Pb3 / Brass CuZn36Pb3       
            
  Overall 
 
350  N 
Inner Conductor 
Cable data                         
    
                
 
 
   
 
Plating 
 
  Torsional Strength 
 
Body Parts 
Nitin-6             
  (Connector / Cable)  
 *NATM    
Inner Conductor 
Cable data             
   
 
 
 
  Test performed by 
 Troels V. Kristensen 
Insulators 
    -                   
  Date of release 
 March 13,  2008 
 
 
Remarks 
*  Not Able To Measure(NATM): The cable starts to twist without the connector loosing its grip.