Gepco 61801EZ-7.41 User Manual

Page of 112
85
Gepco International, Inc.  
P.
800.966.0069
P. 847
.795.9555  F
. 847
.795.8770  www
.gepco.com
NETWORK CABLES
NETWORK CABLES
Gepco Category 6 and 6+ cables feature extended band-
widths and precision tolerances to meet or exceed the
latest TIA/EIA and ISO standards.  Designed to deliv-
er reliability in leading-edge networking, data, and
video applications, every reel is ETL verified to
ensure consistent performance. Available in
both plenum and riser constructions, Gepco
Category 6 and 6+ cables can be installed
in a variety of applications and environ-
ments.
Category 6 Network
Mechanical Specifications
Part #
# of
Pairs
Nominal
OD
Conductors
Insulation
Jacket
UL
Type
Weight
CT604/250
4
.220”
23 AWG Solid BC
Polyolefin
PVC
CMR
28 lbs/Mft
Category 6 Four-pair 250MHz
CT604/250P
4
.215”
23 AWG Solid BC
3 Pairs FEP/1 Pair FR Polyolefin
Plenum PVC
CMP
28 lbs/Mft
Category 6 Four-pair 250MHz: Plenum
CT604/500
4
.248”
23 AWG Solid BC
Polyolefin
PVC with Central Spacer
CMR
28 lbs/Mft
Category 6 Four-pair 500MHz
CT604/500P
4
.235”
23 AWG Solid BC
3 Pairs FEP/1 Pair FR Polyolefin
Plenum PVC with Central Spacer
CMP
31 lbs/Mft
Category 6 Four-pair 500MHz: Plenum
Electrical Specifications
Part #
DCR Max
(1000’)
DCR
Unbal. Max
Char.
Imped.
Prop. Delay
(Skew) Max
Vel. of Prop.
(Nonplenum, Plenum)
Standards
CT604/250
Series
27.2 
S
3% 
100 
S (+/-15)
35 ns/100m
70%, 72%
Meets or Exceeds TIA/EIA-568-B.2-1
Cat 6, ISO/IEC 11801 Ed. 2.0
Freq. (MHz)
1
4
10
16
20
31.25
62.5
100
200
250
350
400
500
Insertion Loss (db/100m) (max)
2.0
3.8
5.9
7.5
8.4
10.6
15.3
19.7
28.8
32.7
39.6
42.7
48.7
PSACR (dB/100m) (min)
71.3
60.5
52.4
47.7
45.4
40.3
31.1
23.6
9.9
4.6
ACR (dB/100m) (min)
73.3
62.5
54.4
49.7
47.4
42.3
33.1
25.6
11.9
6.6
2.0
PSNEXT (dB/100) (min)
73.3
64.3
58.3
55.3
53.8
50.9
46.4
43.3
38.8
37.3
35.2
34.3
32.8
NEXT (dB/100) (min)
75.3
66.3
60.3
57.3
55.8
52.9
48.4
45.3
40.8
39.3
37.2
36.3
34.8
PSELFEXT (dB/100m) (min)
65.8
53.8
45.8
41.7
39.8
37.8
29.9
25.8
19.8
17.8
ELFEXT (dB/100m) (min)
68.8
56.8
48.8
44.7
42.8
38.9
32.9
28.8
22.8
20.8
Return Loss (dB) (min)
20.0
23.0
25.0
25.0
25.0
23.6
21.5
20.1
18.0
17.3
LCL (dB/100m) (min)
50.0
44.0
40.0
38.0
37.0
35.1
32.0
30.0
27.0
26.0
ELTCTL (dB/100m) (min)
35.0
23.0
15.0
10.9
9.0
5.1
CT604/500
Series
27.2 
S
3% 
100 
S (+/-15)
45 ns/100m
70%, 72%
Meets or Exceeds TIA/EIA-568-B.2-1
Cat 6, ISO/IEC 11801 Ed. 2.0
Freq. (MHz)
1
4
10
16
20
31.25
62.5
100
200
250
300
350
400
500
Insertion Loss (db/100m) (max)
2.0
3.7
5.8
7.4
8.3
10.5
15.1
19.4
28.4
32.2
35.7
39.0
42.1
48.0
PSACR (dB/100m) (min)
74.3
63.6
55.5
50.8
48.5
43.4
34.3
26.9
13.4
8.1
3.4
0.1
ACR (dB/100m) (min)
76.3
65.6
57.5
52.8
50.5
45.4
36.3
28.9
15.4
10.1
5.4
1.1
PSNEXT (dB/100) (min)
76.3
67.3
61.3
58.2
56.8
53.9
49.4
46.3
41.8
40.3
39.1
38.1
37.3
35.8
NEXT (dB/100) (min)
78.3
69.3
63.3
60.2
58.8
55.9
51.4
48.3
43.8
42.3
41.1
40.1
39.3
37.8
PSELFEXT (dB/100m) (min)
68.8
56.8
48.8
44.7
42.8
38.9
32.9
28.8
22.8
20.8
19.3
17.9
16.8
14.8
ELFEXT (dB/100m) (min)
71.8
59.8
51.8
47.7
45.8
41.9
35.9
31.8
25.8
23.8
22.3
20.9
19.8
17.8
Return Loss (dB) (min)
20.0
23.0
25.0
25.0
25.0
23.6
21.5
20.1
18.0
17.3
16.8
16.3
15.9
15.2
LCL (dB/100m) (min)
40.0
40.0
40.0
38.0
37.0
35.1
32.0
30.0
27.0
26.0
ELTCTL (dB/100m) (min)
35.0
23.0
15.0
10.9
9.0
5.1
Features & Benefits
Low Insertion Loss, Crosstalk, &
Return Loss
Precision 100
S Impedance
Four Twisted-pairs
Characterized up to or Beyond
TIA/EIA Standards
Category 6 Compliant
ETL Verified
Riser & Plenum Versions
Applications
Ethernet or Gigabit Ethernet
High Data-rate Applications