Gepco HDC160 HDC160.99 User Manual

Product codes
HDC160.99
Page of 44
www.gepco.com | 800.966.0069
FIBER SYSTEM SOLUTIONS
38
Exceptionally rugged, light-weight, single-mode fiber optic cables for
portable applications in harsh environments.  Available in both dis-
tribution and breakout style constructions, all tactical cables fea-
ture  an  abrasion-,  chemical-,  and  cut-resistant  outer
polyurethane jacket.   The 125µm single-mode fiber elements
are  coated  with  a  900µm,  hard  elastomeric,  tight-buffer.
Available in two series, the distribution series features an
armid  strength  member  filler  for  exceptional  strength,
while the breakout series features armid strength mem-
bers within a tube elastomeric jacket for each fiber to
provide additional strength and crush resistance.
Single-mode Optical Fiber: Tactical
Exceptionally Rugged
Crush Resistant
Low-loss Single-mode Fiber
Distribution & Breakout Type 
Constructions
Armid Filler
Polyurethane Outer Jacket
Meets or Exceeds TIA/EIA Mil
F E AT U R E S   &   B E N E F I T S
Mechanical Specifications
Part #
Fiber
Buffer
Outer
Jacket
Crush
Resistance
Impact
Resistance
Flex
Resistance
Operating
Temp.
Storage
Temp.
Number
of
Elements
Nominal
OD
Tensile Load
Minimum Bend Radius
Weight
Short
Term
Long
Term
Installation
(Pulling)
Operating
FSD**T
*=Number
of Elements
Acrylate Tight
Buffer Coating
( .9mm OD)
with Overall
Kevlar Filler
PU,
Black
440
N/cm
200
Impacts
2000
Cycles
-55°C
to
+85°C
-70°C
to
+85°C
2
.200”
1,800 lbs
600 lbs
3.2”
1.6”
15 lbs/Mft
4
.220”
1,800 lbs
600 lbs
3.6”
1.8”
19 lbs/Mft
6
.240”
1,800 lbs
600 lbs
3.8”
1.9”
19 lbs/Mft
8
.260”
1,800 lbs
600 lbs
4.2”
2.1”
26 lbs/Mft
10
.260”
2,100 lbs
700 lbs
4.2”
2.1”
30 lbs/Mft
12
.260”
2,100 lbs
700 lbs
4.2”
2.1”
34 lbs/Mft
18
.300”
2,400 lbs
800 lbs
4.8”
2.4”
40 lbs/Mft
24
.330”
3,000 lbs
1000 lbs
5.4”
2.7”
50 lbs/Mft
Tactical Single-mode Fiber: Distribution
FSB**T
*=Number
of Elements
Acrylate Tight
Buffer Coating
( .9mm OD)
with Kevlar
Filler & PVC
Tube Jacket
for Each Fiber
PU,
Black
440
N/cm
200
Impacts
2000
Cycles
-55°C
to
+85°C
-70°C
to
+85°C
.260”
2,200 lbs
550 lbs
4.2”
2.1”
21 lbs/Mft
4
.290”
2,200 lbs
550 lbs
4.6”
2.3”
28 lbs/Mft
6
.340”
2,400 lbs
600 lbs
5.4”
2.7”
36 lbs/Mft
8
.390”
3,200 lbs
800 lbs
6.2”
3.1”
50 lbs/Mft
10
.450”
4,000 lbs
1000 lbs
7.2”
3.6”
59 lbs/Mft
12
.480”
4,800 lbs
1200 lbs
7.6”
3.8”
65 lbs/Mft
18
.570”
7,200 lbs
1,800 lbs
9.2”
4.6”
73 lbs/Mft
24
.570”
9,600 lbs
2,400 lbs
9.2”
4.6”
105 lbs/Mft
Tactical Single-mode Fiber: Breakout
Fiber Specifications
Type
Mode Field Diameter
Cladding Diameter
Maximum Attenuation
Single-mode
8.3 µm
125 µm
≤ 0.50 dB/Km @ 1310/1550nm