Gepco HDC160 HDC160.41 User Manual

Product codes
HDC160.41
Page of 44
www.gepco.com | 800.966.0069
FIBER SYSTEM SOLUTIONS
32
Extra-durable 12mm Hybrid Fiber cable for improved durability in
High Definition camera to CCU interconnects.  In addition to the
steel strength member and nylon-based polymer fiber coating,
each fiber optic element has a Kevlar wrap and PVC jacket for
greater  strength  and  protection.    For  the  power  elements,
HDC120P utilizes two auxiliary conductors for streamlined
termination,  thereby  reducing  the  possibility  of  electrical
faults.  All copper elements now feature heat-resistant PE
insulation  and  are  shielded  by  a  dense  95%  copper
braid.  For additional durability, the outer jacket is made
with an extra-tough polyurethane compound that is ex-
ceptionally abrasion and puncture resistant.
Mechanical Specifications (Series)
Component
Number
Type
Insulation (Type, OD)
Color Code
Optical
2
Single-mode Fiber Optic
(8.3 µm Mode Field, 125 µm Cladding)
CPE Fiber Coating,
Kevlar Wrap,
Tight Tube PVC Jacket,
.062” Finished O.D.
One Blue, One Yellow
Signal
2
24 AWG (19x36) Stranded TC
PE, .044”
One Red, One Gray
Auxiliary
2
16 AWG (65x34) Stranded TC
PE, .084”
One White, One Black
Strength Member
1
16 AWG Stranded Steel
PVC, .087”
One White
Mechanical Specifications
Part #
Nominal OD
Master Jacket (Type, Colors)
Overall Shield
Approx. Weight
HDC120P
12.0mm
Polyurethane, Black
95% TC Braid
135 lbs/Mft
Heavy-duty 12mm Hybrid Fiber Camera Cable
Electrical & Optical Specifications
Fiber
Attenuation
Signal
Conductor
DCR
Power
Conductor
DCR
Shield
DCR
Insulation
Resistance
(Power or Signal)
Dielectric
Strength
(Power or Signal)
Operating
Temperature
SMPTE
Standard
<0.70 dB/km
@ 1310/1550nm
23.8 S/Mft
4.5 S/Mft
2.6 S/Mft
>10M S/km
3000 Volts RMS
@ 20°C, 60Hz for 1 min.
-40°C to +75°C
(@ 0 to 95% humidity)
311M Compliant
(Meets or Exceeds)
12mm Heavy-duty Hybrid Fiber Optic
Heavy-duty Polyurethene Jacket
Ultra-low Attenuation
SMPTE 311M Compliant
Single-mode Optical Fibers with Kevlar & PVC
Jackets
Proprietary Fiber Coating for Increased Tensile
Strength
Four Large-gage Copper Conductors
Heat Resistant
Strength Member for Additional Durability
F E AT U R E S   &   B E N E F I T S