Panduit SmartZone ZESMA05-01 Leaflet

Product codes
ZESMA05-01
Page of 2
SmartZone
 Smoke Sensor
S p e c i f i c a t i o n   S H e e t
k e y   f e a t u r e s   a n d   b e n e f i t s
Smoke and 
fire monitoring
Monitors and detect early signs of smoke and fire in and around a rack, cabinet or room in a data center or facility as 
part of a comprehensive environmental monitoring system
Optical detection
Mains powered smoke sensor with audible alarm that uses a ‘green' optical detection unit rather than 
ionization techniques
RJ45 connection 
Utilizes an RJ45 plug socket to allow standard patch cable connection to a SmartZone
 Gateway port, avoiding time 
delays during deployment
Gateway-hosted IP 
address  
Connects to a SmartZone™ Gateway device that captures sensor and other device data through one single 
Gateway IP address, reducing the need for separate IP ports, IP capital costs, and management overhead; 
no setup required; the gateway will automatically recognize this as an smoke sensor and auto-configure itself
Versatile mounting  
Offers versatile mounting options to accommodate easy indoor deployment within a room
SmartZone
™ 
Software 
Suite integration 
Captures environmental data that is consolidated by connected gateways and then utilized by SmartZone
 Software 
Suite modules for real-time monitoring and display, management, and automated documentation
t e c h n i c a l   i n f o r m a t i o n
Dimensions:                                          4 in. x 2 in. (101mm x 55mm) diameter
Mounting:                                               2.6 in. x 0.1 in. (65mm x 4mm) diameter
Network patch cable length:                  Supplied with 2m cable terminating in RJ45
IP rating:                                                IP23D (EN60529)
Operating temperature:                         -4°F to 140°F (-20°C to 60°C)
Storage temperature range:                  -22°F to 248°F (-30°C to 120°C) 
Operating temperature range:               0% RH to 90% RH (non-condensing) 
Weight:                                                  0.22 lbs (99g); with base: 0.33 lbs. (150g)
Certifications:                                        EN54; 2000 with LPCB, Vds, DIBT, BOSEC, FG, EN61000-6-4, EN61000-6-3, EN50155
s p e c i f i c a t i o n s
The smoke sensor will detect smoke and fire in and around a rack, cabinet or room in a data 
center. The smoke sensors will be installed as part of a primary/secondary topology, where the 
captured data is transmitted to, and retained within, a connected gateway device. This data can 
be used to display baseline operational data through connected gateway firmware or through 
the SmartZone™ Software Suite platform.
www.panduit.com
a p p l i c a t i o n s
Panduit
®
 SmartZone
 Solutions enable comprehensive energy and physical infrastructure efficiency in data centers, facility domains, and 
enterprise estates through intelligent software, hardware, and services that provide granular visibility of power, space, environmental, asset, 
and connectivity information that is accurate and actionable for operational optimization. 
Panduit
®
 SmartZone
 Smoke Sensors enable immediate data capture and alerting of potentially fatal smoke or fire conditions at different IT 
and facility domain points, in either new or retrofit installations. These sensors are designed for indoor mounting to a ceiling or wall in a data 
center or facility.     
Panduit
®
 SmartZone
™ 
 Smoke Sensors connect directly to SmartZone
 Gateways via a supplied standard network patch cable and transmit 
real-time environmental information through the gateway platforms to SmartZone
 Software to provide notification of exceeded thresholds, 
quickly identify and resolve issues and automate collection of real-time and accurate information.