MIPRO ACT-50H ACT 50H(6A) User Manual

Product codes
ACT 50H(6A)
Page of 5
BATTERY STATUS 
Indicates the power remaining in the transmitter 
battery. When the battery has less than 10% power 
remaining it must be replaced or recharged. If an 
under voltage condition continues, the LCD will 
show “Poff” and the system will shut down to 
prevent being overly discharged.
“Poff” - Power Off : 
100%
80%
40%
10%
0%
When the power switch is turned off, the LCD will 
show “Poff” (for Power Off) first and then the 
system will shut down and no further messages will 
be displayed.
ERR
GROUP CHANNEL BAT
LCD SCREEN
!
ERR Message: When “ERR” appears in the display it 
indicates that an operational error has occurred. Please 
refer to the following codes to diagnose which error you 
are experiencing.
ERR no01
EEPROM is not being programmed or 
internal data error.
ERR no02
For testing only.
ERR no03
The frequency you want to program is 
above the switching bandwidth of the 
transmitter.  Use a receiver with an 
appropriate frequency group. (At this time 
the microphone is still operating and the 
frequency remains unchanged. To clear the 
displayed "ERR" message, switch the 
handheld transmitter off and on again.)
ERR no04
The frequency you want to program is 
below the switching bandwidth of the 
transmitter.  Use a receiver with an 
appropriate frequency group. (At this time 
the microphone is still operating and the 
frequency remains unchanged. To clear the 
displayed “ERR” message, switch the 
handheld transmitter off and on again.)
!
“Group” & “Channel”: When both the group and 
channel numbers are displayed, it means that you are 
using the pre-programmed frequency of the receiver.
!
“Channel” Only: If “Channel” only is displayed, it 
means that you are using a frequency which is not pre-
programmed.
Handheld Transmitter
Handheld Transmitter
5
6