HP 3PAR StoreServ E7X67A User Manual

Product codes
E7X67A
Page of 67
QuickSpecs  
HP 3PAR StoreServ 7000 Storage 
Technical Specifications 
 
 
 
c04164476 — DA – 14433  Worldwide — Version 31 — December 01, 2014 
Page 42 
 
LFF SAS drive with carrier 
1.18/30.0
**
 
4.36/110.84
**
 
8.67/220.26 
1.9/0.86  
(varies by type) 
* includes length of ejector handles 
** includes RFI clips 
Power Requirements 
  
Input Voltage (VAC) 
100 - 240 VAC 
Frequency (Hz) 
50 - 60 
  
  
Component 
Idle 
(watts / BTU/hr) 
Transactional 
(watts / BTU/hr) 
Node Pair (7200/7200c or 7400/7400c), 
no drives, no add-on host adapters 
236 / 803 
398 / 1357 
Node Pair (7440c), no drives, no add-on 
host adapters 
344 / 1173 
363 / 1238 
4-port 8Gb/s Fibre Channel Adapter 
24 / 81.7 
32.6 / 111 
2-port 10Gb/s iSCSI/FCoE Adapter 
34 / 115.8 
40 / 136.4 
HP M6710 2.5 inch 2U SAS Drive Enclosure, 
no drives 
150 / 512 (average) 
150 / 512 (average) 
HP M6720 3.5 inch 4U SAS Drive Enclosure, 
no drives 
164 / 559 (average) 
164 / 559 (average) 
300GB 15K Small Form Factor HDD 
6.2 / 21.1 
8.0 / 27.3 
450GB 10K Small Form Factor HDD 
3.7 / 12.6 
6.3 / 21.5  
600 GB 10K Small Form Factor HDD 
4.1/14  
6.3/21.5 
900GB 10K Small Form Factor HDD 
4.8 / 16.4 
6.2 / 21.1 
1.2TB 10K Small Form Factor HDD 
3.6/12.3 
7.8/26.6 
1 TB 7.2k Small Form Factor HDD 
2.95/10.1 
3.84/13.1 
2TB 7.2K Large Form Factor NL HDD 
7.5 / 25.6 
10.6 / 36.1 
3TB 7.2K Large Form Factor NL NDD 
8.5 / 28.9 
11.8 / 40.2 
200GB SLC SSD 
1.4 / 4.8 
3.9 / 13.3 
480GB MLC SSD 
2.2/ 7.5 
5.5/18.7 
920GB MLC SSD 
2.2/7.5 
5.5/18.7 
480GB cMLC SSD 
3.2/11 
7.1/24.4 
1920GB cMLC SSD 
3.5/11.9 
8.9/30.5 
 
Environmental Specifications 
 
 
   
Operating Temperature 
 
41° to 104° F (5° to 40° C) - Reduce rating by 1° F for each 1000 ft altitude (1.8° 
C/1,000 m) 
Shipping Temperature 
 
32° to 140° F (0° to 60° C) 
Altitude (ft/m) max. 
 
10,000 ft / 3,048 m 
Shipping Altitude (ft/m) max. 
 
40,000ft/ 12,192 m 
Humidity 
 
10% to 90% non condensing 
Shipping Humidity  
 
10% to 90% non condensing