Typical Electric Lock Connection 
2N®  Helios  contains  a  solid-state  switch  equipped  with  V-MOS  transistors,  which is 
able to switch both ac  and dc regardless  of polarity. Make  sure that the current and 
voltage values do not exceed limits (refer to the Technical Data) and that the technical 
parameters of the lock and power supply are compatible. 
 
Fig.: Lock Connection 
Varování 
 
Never switch 230 or 120 V mains voltage directly!!! 
If  you  do  not  have  an  electric  lock  and  want  to  have  one,  you  should  select  a  12 
V lock,  this  being  the  most  common  type.  Connect  the  lock  according  to  the  figure, 
which shows the button backlight supply too (see later). 
Dc-supplied lock: Practically all locks can be dc and ac supplied. The ac supply is more 
advantageous  because  the  lock  buzzes,  which  is  the  clearest  signalling  method 
however to use a dc supply lock (from batteries, e.g.), you are recommended to equip 
2N®  Helios  with  acoustic  signalling  (continuous  tone  during  the  whole  switch 
activation time). 
 Caution 
 
If  the  lock  power  supply  fails  and  the  telephone  system  carries  on 
working,  the  keypad-equipped  2N®  Helios  system  is  unaware  of  the 
failure  the  switch  will  be  password-activated  and  the  activation  is 
acoustically  signalled,  but  the  electric  lock  will  not  work  because  of  the 
lack of power. 
Electric 
door 
lock 
Power 
supply 12V 
AC or DC 
Tel. 