Fujitsu RX300 S8 VFY:R3008SC020IN/R6 Data Sheet

Product codes
VFY:R3008SC020IN/R6
Page of 12
Data Sheet
 FUJITSU Server PRIMERGY RX300 S8 Dual socket 2U rack server 
Page 4 / 12
www.fujitsu.com/fts
Interfaces
Graphics (15-pin)
2 x VGA (thereof 1x front optional)
Serial 1 (9-pin)
1 x serial RS-232-C,  usable for iRMC or system or shared
LAN / Ethernet
2 x Gbit/s Ethernet (RJ45) with upgrade options for additional 2x1 Gbit/s (RJ45), 4x 1 Gbit/s (RJ45) or 2x 10 Gbit/s (SFP+)
Management LAN (RJ45)
1 x dedicated management LAN port for iRMC S4  (10/100/1000 Mbit/s)
Management LAN traffic can be switched to shared onboard Gbit LAN port 
or optional Modular LAN 2x10 Gbit controller
Front Service LAN port as option
Onboard or integrated Controller
RAID controller
4 port for internal 3G SATA and SAS (as upgrade option with SAS enabling key) for HDDs with RAID 0/1/10 or SAS LTO 
device  (Intel C600)
additional RAID controller options are described under Components RAID controller
SATA Controller
Intel® C600, 1 x SATA channel for ODD
LAN Controller
Intel® Ethernet Controller I350. 2 x 10/100/1000 Mbit/s Ethernet (I/O acceleration). Modular integrated on-board LAN  
offers upgrade options for additional 2x1 Gbit/s , 4x 1 Gbit/s or 2x 10 Gbit/s.
PXE-Boot via LAN from PXE server, iSCSI boot (also diskless) 
Remote management controller
Integrated Remote Management Controller (iRMC S4, 256 MB attached memory incl. graphics controller)
IPMI 2.0 compatible
Trusted Platform Module (TPM)
Infineon / separate module; TCG V1.2 compliant (option)
Slots
PCI-Express 3.0 x8
5 x Low profile 
PCI-Express 3.0 x16
2 x Low profile (2nd processor required)
Slot Notes
One PCIe Gen3 x8 slot may be occupied with a Modular integrated on-board LAN controller if configured.
One PCIe Gen3 x8 slot may be occupied with a Modular RAID controller if configured.
Important: 5 PCIe x8 slots are supported with the first processor. 7 PCIe slots (including 2 PCIe x16) are supported with 
two processors.
Possible slot length described in relevant system onfigurator. 
Drive bays
Storage drive bays
2.5-inch base unit (max. 16 x 2.5) or 3.5-inch base unit (max. 6 x 3.5)
Accessible drive bays
1 x 5.25/0.5-inch for ODD
1 x 5.25/0.5-inch for Local Service Display 
1 x 3.5/1.6-inch for backup devices
1 x 5.25/1.6-inch for backup devices
Notes accessible drives
All possible options described in relevant system configurator.
Drive bays (Base unit specific)
Storage drive bays
Max 6 x 3.5-inch
Max 8 x 2.5-inch
Max 12 x 2.5-inch
Max 16 x 2.5-inch
Optional accessible drives
1x 3.5/1.6-inch bay for 
backup devices (occupies 2x 
3.5-inch HDD)
LTO 5.25” or DAT/RDX 3.5” 
possible
General system information
Number of fans
5
Fan configuration
redundant / hot-plug
Fan notes
4+1 redundant
Operating panel
Operating buttons
On/off switch
Reset button
NMI button
ID button