HGST HCS5C3232SLA380 User Manual

Page of 261
 
HITACHI CinemaStar 5K 320 Hard Disk Drive specification (Rev 1.21) 
128 
11.13    Initialize Device Parameters (91h)
 
 
 
Command Block Output Registers
 
 
Command Block Input Registers
 
Register
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
 
Register
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
Data
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Data
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Feature
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Error
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Sector Count
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
V
 
 
Sector Count
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Sector Number
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Sector Number
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Cylinder Low
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Cylinder Low
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Cylinder High
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
 
Cylinder High
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Device/Head
 
1
 
-
 
1
 
D
 
H
 
H
 
H
 
H
 
 
Device/Head
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
-
 
Command
 
1
 
0
 
0
 
1
 
0
 
0
 
0
 
1
 
 
Status
 
...See Below...
 
 
 
Error Register
 
 
Status Register
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
 
7
 
6
 
5
 
4
 
3
 
2
 
1
 
0
 
CRC
 
UNC
 
0
 
IDN
 
0
 
ABT
 
T0N
 
AMN
 
 
BSY
 
RDY
 
DF
 
DSC
 
DRQ
 
COR
 
IDX
 
ERR
 
0
 
0
 
0
 
0
 
0
 
V
 
0
 
0
 
 
0
 
V
 
0
 
-
 
-
 
0
 
-
 
V
 
Table 90    Initialize Device Parameters Command (91h) 
 
 
The  Initialize  Device  Parameters  command  enables  the  host  to  set  the  number  of  sectors  per  track  and  the 
number of heads minus 1, per cylinder. Words 54-58 in Identify Device Information reflect these parameters. 
The parameters remain in effect until following events: 
   
Another Initialize Device Parameters command is received. 
   
The device is powered off. 
   
Soft reset occurs and the Set Feature option of CCh is set instead of 66h. 
Output Parameters To The Device 
Sector Count 
The number of sectors per track. 0 does not mean there are 256 sectors per track, but 
there is no sector per track. 
H 
The number of heads minus 1 per cylinder. The minimum is 0 and the maximum is 15. 
Note: The following conditions needs to be satisfied to avoid invalid number of cylinders beyond FFFFh. 
 
 
(Total number of user addressable sectors)/((Sector Count)*(H+1)) = < FFFFh 