137 
 
Output Parameters To The Device 
Feature 
Log Address Specific 
Sector Count Current 
The number of sectors to be read from the specified log low order, bits (7:0).   
The log transferred by the drive shall start at the sector in the specified log at the 
specified offset, regardless of the sector count requested. 
Sector Count Previous
 
The number of sectors to be read from the specified log high orders, bits (15:8).
 
Sector Number Current 
The log to be returned as described in 0. 
Cylinder Low Current   
The first sector of the log to be read low order, bits (7:0). 
Cylinder Low Previous 
The first sector of the log to be read high order, bits (15:8). 
 
Log address
 
Content
 
Feature set
 
Type
 
00h
 
Log directory
 
N/A
 
Read Only
 
03h
 
Extended Comprehensive SMART error log
 
SMART error logging
 
Read Only
 
06h
 
SMART self-test log
 
SMART self-test
 
See Note
 
07h
 
Extended SMART self-test log
 
SMART self-test
 
Read Only
 
10h 
Command Error 
Native Command Queuing 
Read Only 
11h 
Phy Event Counters 
Serial ATA 
Read Only 
20h
 
Streaming Performance log
 
Streaming
 
Read Only
 
21h
 
Write Stream Error log
 
Streaming
 
Read Only
 
22h
 
Read Stream Error log
 
Streaming
 
Read Only
 
80h-9Fh
 
Host vendor specific
 
SMART
 
Read/Write
 
Note: If log address 06h is accessed using the Read Log Ext or Write Log Ext commands, command abort shall be 
returned. 
Note: Please see 9.20.3 about Phy Event Counter. 
Table 96    Log Address Definition
 
 
The Extended SMART self-test log sector shall support 48-bit and 28-bit addressing. All 28-bit entries contained 
in the SMART self-test log sector shall also be included in the Comprehensive SMART self-test log sector with 
the 48-bit entries. 
If the feature set associated with the log specified in the Sector Number register is not supported or enabled, or if 
the  values  in  the  Sector  Count,  Sector  Number  or  Cylinder  Low  registers  are  invalid,  the  device  shall  return 
command aborted.