HGST HCS5C3232SLA380 User Manual

Page of 261
 
HITACHI CinemaStar 5K 320 Hard Disk Drive specification (Rev 1.21) 
160 
Completion Time Limit event if some data transferred is in error. 
Output Parameters To The Device 
Feature Current 
 
      URG (bit7) 
URG  specifies  an  urgent  transfer  request.    The  Urgent  bit  specifies  that  the 
command should be completed in the minimum possible time by the device and 
shall be completed within the specified Command Completion Time Limit. 
      RC    (bit6) 
RC specifies Read Continuous mode enabled.    If the Read Continuous bit is set 
to one, the device shall not stop execution of the command due to errors. 
If the RC bit is set to one and errors occur in reading or transfer of the data, the 
device shall continue to transfer the amount of data requested and then provide 
ending  status  with  BSY  bit  cleared  to  zero,  the  SE  bit  set  to  one,  the  ERR  bit 
cleared to zero, and the type of error, ICRC, UNC, IDNF or ABRT reported in the 
error log. 
If the RC bit is set to one and the CCTL expires, the device shall stop execution 
of the command and provide ending status with the BSY bit cleared to zero, the 
SE bit set to one, the ERR bit cleared to zero, and report the fact that the CCTL 
expired by setting the CCTO bit in the error log to one. 
In  all  cases,  the  device  shall  attempt  to  transfer  the  amount  of  data  requested 
within the CCTL even if some data transferred is in error. 
      NS (bit5) 
NS (Not Sequential) may be set to one if the next read stream command with the 
same Stream ID may not be sequential in LBA space.   
      HSE (bit4) 
HSE (Handle Stream Error) specifies that this command starts at the LBA of the 
last  reported  error  for  this  stream,  so  the  device  may  attempt  to  continue  its 
corresponding error recovery sequence where it left off earlier. 
      Stream ID (bit 0..2) 
Stream ID specifies the stream to be read.    The device shall operate according 
to the Stream ID set by the Read Stream command.     
Feature Previous 
      CCTL (7:0) 
 
The time allow
ed for the current command‘s completion is calculated as follows: 
        Command  Completion  Time  Limit  =  (content  of  the  Feature  register                                 
Previous) * (Identify Device words (99:98)) useconds 
If  the  value  is  zero,  the  device  shall  use  the  Default  CCTL  supplied  with  a 
previous  Configure  Stream  command  for  this  Stream  ID.    If  the  Default  CCTL     
is zero, or no previous Configure Stream command was defined for this Stream 
ID, the drive will ignore the CCTL.    The time is measured from the write of the 
command register to the final INTRQ for command completion.  The device has 
minimum  CCTL  value.  When  the  specified  value  is  shorter  than  the  minimum 
value,  CCTL  is  set  to  the  minimum  value.  Actual  minimum  CCTL  value  is 
described in the 
―Deviations from Standard‖ section. 
Sector Count Current 
The number of continuous sectors to be transferred low order, bits (7:0) 
Sector Count Previous 
The  number  of  continuous  sectors  to  be  transferred  high  order,  bits  (15:8).    If 
zero  is  specified  in  the  Sector  Count  register,  then  65,536  sectors  will  be 
transferred. 
Sector Number Current 
LBA (7:0). 
Sector Number Previous 
LBA (31:24). 
Cylinder Low Current 
LBA (15:8). 
Cylinder Low Previous 
LBA (39:32). 
Cylinder High Current 
LBA (23:16). 
Cylinder High Previous 
LBA (47:40). 
 
 
Input Parameters From The Device 
Sector Number (HOB=0) 
LBA (7:0) of the address of the first unrecoverable error. 
Sector Number (HOB=1) 
LBA (31:24) of the address of the first unrecoverable error. 
Cylinder Low (HOB=0) 
LBA (15:8) of the address of the first unrecoverable error.