HGST HCS5C3232SLA380 User Manual

Page of 261
 
HITACHI CinemaStar 5K 320 Hard Disk Drive specification (Rev 1.21) 
81 
9.21.2.3.3 
Format of SCT Status Response   
Byte 
Type 
Field Name 
Value 
Description 
1:0 
Word 
Format Version 
0003h 
Status Response format version number 
3:2 
Word 
SCT Version 
 
Manufacturer‘s 
vendor 
specific 
implementation version number 
5:4 
Word 
SCT Spec. 
0001h 
Highest  level  of  SCT  Technical  Report 
supported 
9:6 
DWord 
Status Flags 
 
Bit 0 : Segment Initialized Flag 
  If  this  bit  is  set  to  1,  an  LBA  Segment 
Access  command  write  to  all  LBAs  of  the 
drive  has  completed  without  error.  This  bit 
shall be cleared to 0 when any user LBA is 
written, even if write cache is enabled. This 
bit is alse cleared if the capacity of the drive 
is  changed  via  SETMAX,  SETMAX  EXT  or 
DCO. This bit is preserved through a power 
cycle. 
Bit 1-31 : Reserved 
10 
Byte 
Drive Status 
 
0 = Active waiting for a command   
1 = Stand-by 
2 = Sleep 
3 = DST executing in background 
4 = SMART ODC executing in background 
5 = SCT executing in background 
13:11 
Byte[3] 
reserved 
00h 
 
15:14 
Word 
Extended 
Status 
Code 
 
Status  Of  last  SCT  command  issued. 
FFFFh  if  SCT  command  executing  in 
background. 
17:16 
Word 
Action Code 
 
Action code of last SCT command issued. If 
the Extended Status Code is FFFFh, this is 
the  Action  Code  of  the  command  that  is 
current executing. 
19:18 
Word 
Function Code 
 
Function  code  of  last  SCT  command 
issued.  If  the  Extended  Status  Code  is 
FFFFh,  this  is  the  Function  Code  of  the 
command that is current executing. 
39:20 
Byte[20] 
reserved 
00h 
 
47:40 
QWord 
LBA 
 
Current  LBA  of  SCT  command  executin  in 
background.  If  there  is  no  command 
currently  executing  in  the  background,  this 
field is undefined. 
199:48    Byte[152]   
00h 
 
200 
Byte 
HDA Temp 
 
Current  HDA  temperature  in  degrees 
Celsius. This is a 2‘s complement number. 
80h indicates that this value is invalid. 
201 
Byte 
Min Temp 
 
Minimum  HDA  temperature  in  degrees 
Celsius.  This  is  a  2‘s  complement  integer. 
80h indicates that this value is invalid. 
202 
Byte 
Max Temp 
 
Maximum  HDA  temperature  in  degrees 
Celsius. This is a 2‘s complement number. 
80h indicates that this value is invalid. 
203 
Byte 
Life Min Temp 
 
Minimum  HDA  temperature  in  degrees 
Celsius seen for the life of the device. This 
is  a  2‘s  complement  integer.  80h  indicates 
that this value is invalid. 
204 
Byte 
Life Max Temp 
 
Maximum  HDA  temperature  in  degrees 
Celsius seen for the life of the drive. This is 
a  2‘s  complement  number.  80h  indicates 
that this value is invalid.