Slew Rate Definitions for Single-Ended Input Signals
See 7.5 “Address / Command Setup, Hold and Derating” on “DDR3L Device Operation” for single-ended 
slew rate definitions for address and command signals.
See 7.6 “Data Setup, Hold and Slew Rate Derating” on “DDR3L Device Operation” for single-ended slew 
rate definition for data signals.
lew Rate Definitions for Differential Input Signals
Input slew rate for differential signals (CK, CK and DQS, DQS) are defined and measured as shown in table 
and figure below.
Notes:
The differential signal (i.e. CK-CK and DQS-DQS) must be linear between these thresholds.
 Differential Input Slew Rate Definition for DQS, DQS and CK, CK
Differential Input Slew Rate Definition
Description
Measured
Defined by
Min
Max
Differential input slew rate for rising edge 
(CK-CK and DQS-DQS)
V
ILdiffmax
V
IHdiffmin
[V
IHdiffmin
-V
ILdiffmax
] / DeltaTRdiff
Differential input slew rate for falling edge 
(CK-CK and DQS-DQS)
V
IHdiffmin
V
ILdiffmax
[V
IHdiffmin
-V
ILdiffmax
] / DeltaTFdiff
Delta 
TFdiff
Delta 
TRdiff
V
IHdiffmin
V
ILdiffmax
0
D
iffere
ntial Input
 Vo
ltag
e (i.e
. D
Q
S-
DQS; 
CK-CK)