Hynix HMT351R7BFR8A-H9T8 User Manual

Page of 74
Rev. 1.2 / Dec. 2011
31 
AC & DC Input Measurement Levels
AC and DC Logic Input Levels for Single-Ended Signals
AC and DC Input Levels for Single-Ended Command and Address Signals
Notes:
1. For input only pins except RESET, Vref = VrefCA (DC).
2. Refer to "Overshoot and Undershoot Specifications" on page 44.
3. The ac peak noise on V
Ref
 may not allow V
Ref
 to deviate from V
RefCA(DC)
 by more than +/-1% VDD (for     
reference: approx. +/- 13.5 mV).
4. For reference: approx. VDD/2 +/- 13.5 mV
5. There levels apply for 1.35 volt (see table above) operation only. If the device is operated at 1.5V (table 
(VIH/L.CA(DC100), VIH/L.CA(AC175), VIH/L.CA(AC150), etc.) apply. The 1.5V levels (VIH/L.CA(DC100), 
VIH/L.CA(AC175), VIH/L.CA(AC150), etc.) do not apply when the device is operated in the 1.35 voltage 
range.
Single Ended AC and DC Input Levels for Command and Address
Symbol
Parameter
DDR3L-800/1066/1333
Unit
Notes
Min
Max
VIH.CA(DC90)
DC input logic high
Vref + 0.09
VDD
V
1
VIL.CA(DC90)
DC input logic low
VSS
Vref - 0.09
V
1
VIH.CA(AC160)
AC input logic high
Vref + 0.160
Note2
V
1, 2
VIL.CA(AC160)
AC input logic low
Note2
Vref - 0.160
V
1, 2
VIH.CA(AC135)
AC Input logic high
Vref + 0.135
Note2
V
1, 2
VIL.CA(AC135)
AC input logic low
Note2
Vref - 0.135
V
1, 2
V
RefCA(DC
)
Reference Voltage for ADD, CMD inputs
0.49 * VDD
0.51 * VDD
V
3, 4