DELL C7008 210-38669 User Manual

Product codes
210-38669
Page of 5
Specifications: C-Series resilient enterprise switches
Dell SKU description
C-Series chassis
C7004 4-slot chassis* with 3 AC power supplies 
C7004 4-slot chassis* with 1 AC power supply
C7004 4-slot chassis* with 3 AC power supplies and variable speed fan
C7004 4-slot chassis* with 1 AC power supply and variable speed fan
C7008 8-slot chassis* with 4 AC power supplies
C7008 8-slot chassis* with 2 AC power supplies
C7008 8-slot chassis* with 4 AC power supplies and variable speed fan
C7008 8-slot chassis* with 2 AC power supply and variable speed fan 
*Chassis includes backplane, switch and route processor module  
and fan subsystem.
Fans 
C7004 enhanced fan subsystem
C7008 enhanced fan subsystem
Line cards
Switch Fabric and Route Processor Module 
6-port 40GbE line card, QSFP+ modules required 
16-port 1/10GbE line card with RJ45 interfaces
8-port 10GbE Line card SFP+ modules required 
4-port 10GbE line card, XFP modules required
8-port 10GbE line card, XFP modules required
48-port GbE line card, SFP modules required
48-port 10/100/1000Base-T line card with RJ45 interfaces
48-port 10/100/1000Base-T line card with RJ45 interfaces and PoE
48-port 10/100/1000Base-T line card with RJ45 interfaces and PoE+
FlexMedia line card: 36 10/100/1000Base-T RJ45 interfaces,  
       8x GbE interfaces and 2x 10 GbE interfaces 
       – SFP modules required
       – SFP+ modules required
FlexMedia line card with PoE: 36 10/100/1000Base-T RJ45  
       interfaces, 8x GbE interfaces and 2x 10GbE interfaces 
       – SFP modules required  
       – SFP+ modules required
 
Redundant power supply 
1200W AC Power Supply Module
1600W AC Power Supply Module
For optics/transceivers and cables, please refer to the respective 
line card in this spec sheet. 
Chassis models
C7008: 8 line card slots 
2 route processor module with integrated switch fabric slots 
8 power supply module slots and 1 fan tray slot 
Size: 13 RU, 22.7 x 17.4 x 14.4” (57.66 x 44.2 x 37.58 cm) (H x W x D) 
Weight with factory-installed components: 55 lbs (24.95 kg) 
Weight fully loaded: 152.27 lbs (69.07 kg) 
ISO 7779 A-weighted sound pressure level: 73.8 dBA at 73.4°F (23°C) 
1600W PSU: 
Nominal input voltage: 100–240V AC 50/60Hz 
Maximum thermal output:   
 
9,235 BTU/h at 100/120V AC, 9,299 BTU/h at 200/240V AC 
Maximum input current per module:  
 
14A at 100V AC, 11 A at 120V AC, 9A at 200V AC, 7A at 240V AC 
Maximum system power input:  
 
9,667KVA at 100/120V AC,12,596KVA at 200/240V AC 
Maximum power consumption:  
 
2,707W at 100/120V AC, 2,726W at 200/240V AC 
1200W PSU: 
Maximum thermal output:  
 
8,055 BTU/h at 100/120V AC, 7,420 BTU/h at 200/240 VAC 
Maximum input current per module: 
 
14A at 100V AC, 12A at 120V AC, 7A at 200V AC, 6A at 240V AC 
Maximum system power input: 
 
8,274KVA at 100/120V AC, 8,088KVA at 200/240V AC 
Maximum power consumption: 
 
2,361W at 100/120V AC, 2,175W at 200/240V AC
C7004: 4 line card slots 
2 route processor module with integrated switch fabric slots 
6 power supply module slots and 1 fan tray slot 
Size: 9 RU, 15.7 x 17.5 x 15.3” (39.88 x 44.45 x 38.86 cm) (H x W x D) 
Weight with factory-installed components: 38 lbs (17.24 kg) 
Weight fully loaded: 86.63 lbs (39.29 kg) 
ISO 7779 A-weighted sound pressure level: 69.3 dBA at 73.4°F (23°C) 
1600W PSU:
Maximum thermal output:  
 
5,618 BTU/h at 100/120V AC, 5,304 BTU/h at 200/240V AC
Maximum input current per module:
 
14A at 100V AC, 11A at 120V AC, 9A at 200V AC, 7A at 240V AC
Maximum system power input:
 
6,897KVA at 100/120V AC, 7,315KVA at 200/240V AC
Maximum power consumption:
 
1,647W at 100/120V AC, 1,555W at 200/240V AC
1200W PSU:
Maximum thermal output:  
 
4,449 BTU/h at 100/120V AC, 4,122 BTU/h at 200/240V AC
Maximum input current per module:
 
14A at 100V AC, 11A at 120V AC, 7A at 200V AC, 6A at 240V AC
Maximum system power input:
 
4,261KVA at 100/120V AC, 4,165KVA at 200/240V AC
Maximum power consumption:
 
1,304W at 100/120V AC, 1,208W at 200/240V AC
Common attributes to both chassis 
19” front rack mountable 
Maximum operating specifications: 
    Temperature: 32° to 104°F (0° to 40°C) 
    Altitude: No performance degradation to 10,000 feet (3,048 meters) 
    Relative humidity: 5 to 85% (RH), non-condensing 
Maximum non-operating specifications: 
    Temperature: -40° to 158°F (-40° to 70°C) 
    Maximum altitude: 15,000 feet (4,572 meters) 
    Relative humidity: 5 to 95% (RH), non-condensing 
Redundancy/Availability
 
1+1 redundant switch fabric and route processor modules
Redundant power supplies/PSUs (Note: all power supplies must  
  be of the same type for switch operation)
C7008: 
3 PSU (redundant) or 2 PSU minimum for 100/120V AC, using  
  either 1600W or 1200W PSU
3 PSU (redundant) or 2 PSU minimum for 200/240V AC, using  
  1200W PSU
2 PSU (redundant) or 1 PSU minimum for 200/240V AC, using  
  1600W PSU
Up to 7+1 redundant PSUs supported
PoE+ operation requires 1600W PSU; PoE operation uses 1600W  
  or 1200W PSU
C7004: 
2 PSU (redundant) or 1 PSU minimum for 100/120, or   
  200/240V AC, using either 1600W or 1200W PSU
Up to 5+1 redundant PSUs supported
PoE+ operation requires 1600W PSU; PoE operation uses 1600W  
  or 1200W PSU
Online insertion and removal of all components
Environmental self-monitoring 
Performance
MAC addresses:  
C7004: 256K, C7008: 512K
IPv4 routes:  
12K
IPv6 routes:  
6K
Switching fabric capacity:  
C7004: 768Gbps (571Mpps)  
 
C7008: 1,536Tbps (1,142Mpps)
Link aggregation:  
8 links per group, 128 groups per chassis
Queues per port:  
4 queues
VLANs:  
1024 VLANs with 4096 tag value support
Line-rate Layer 2 switching:  All protocols, including IPv4 and IPv6 
Line-rate Layer 3 routing:  
IPv4 and IPv6
LAG load balancing:  
Based on Layer 2, IPv4 or IPv6 headers 
Switching latency:  
<5 µs for 64 byte frames 
IEEE compliance
 
802.1AB  LLDP
802.1D 
Bridging, STP
802.1p 
L2 Prioritization
802.1Q 
VLAN Tagging, Double VLAN Tagging, GVRP
802.1s 
MSTP
802.1w 
RSTP
802.1X 
Network Access Control
802.3ab  Gigabit Ethernet (1000BASE-T)
802.3ac  Frame Extensions for VLAN Tagging
802.3ad  Link Aggregation with LACP
802.3ae  10 Gigabit Ethernet (10GBASE-X)
802.3af 
Power over Ethernet
802.3ak  10 Gigabit Ethernet (10GBASE-CX4)
802.3at   Power over Ethernet Plus
802.3ba   40 Gigabit Ethernet on optical ports
802.3i 
Ethernet (10BASE-T)
802.3u 
Fast Ethernet (100BASE-FX, 100BASE-TX)
802.3x 
Flow Control
802.3z 
Gigabit Ethernet (1000BASE-X)
ANSI/TIA-1057 LLDP-MED 
Force10  FRRP (Force10 Redundant Ring Protocol)
Force10  PVST+
MTU 
9,252 bytes 
RFC and I-D compliance
General Internet protocols
768  UDP 
1350  TFTP
793  TCP 
2474  Differentiated Services
854  Telnet 
3164  Syslog
959  FTP  
draft-ietf-bfd-base-03 BFD
1321  MD5
General IPv4 protocols
791 
IPv4 
1812  Routers
792  ICMP  
1858  IP Fragment Filtering
826  ARP 
2131  DHCP (server and relay)
1027  Proxy ARP 
2338  VRRP
1035  DNS (client) 
3021  31-bit Prefixes
1042  Ethernet Transmission   3046  DHCP Option 82
1191  Path MTU Discovery 
3069  Private VLAN
1519  NTPv3 
3128  Tiny Fragment Attack
1542  CIDR 
 
Protection
1542  BOOTP (relay)
General IPv6 protocols
1981  Path MTU Discovery (partial) 2464  Ethernet Transmission
2460  IPv6 
2675  Jumbograms
2461  Neighbor Discovery (partial) 3587  Global Unicast Address
2462  Stateless Address 
 
Format
 
Autoconfiguration 
4291  Addressing 
2463  ICMPv6 
BGP
1997  Communities
2385  MD5
2439  Route Flap Damping
2545  Multiprotocol Extensions
 
for IPv6
2796  Route Reflection
draft-ietf-idr-bgp4-20 BGPv4
draft-ietf-idr-bgp4-20  
 
 Graceful Restart
2842  Capabilities
2858  Multiprotocol Extensions
2918  Route Refresh
3065  Confederations
4360  Extended Communities
4893  4-byte ASN 
5396  4-byte ASN  
  
 
Representation
Multicast
1112  IGMPv1
2236  IGMPv2
3376  IGMPv3
3569  SSM for IPv4
4541   IGMPv1/v2 Snooping
draft-ietf-pim-sm-v2-new-05
 
PIM-SM for IPv4
1155  SMIv1
2385  MD5
1156  Internet MIB
1157  SNMPv1
1212  Concise MIB Definitions
1215  SNMP Traps
1493  Bridges MIB
1850  OSPFv2 MIB
1901  Community-based 
  
SNMPv2
2011  IP MIB
2012  TCP MIB
2013  UDP MIB
2024  DLSw MIB
2096  IP Forwarding Table MIB
2570  SNMPv3
2571  Management Frameworks
2572  Message Processing and 
  
Dispatching
2574  SNMPv3 USM
2575  SNMPv3 VACM
2576  Coexistence Between 
  
SNMPv1/v2/v3
2578  SMIv2
2579  Textual Conventions for
  
SMIv2
2580  Conformance Statements
  
for SMIv2 
2618  RADIUS Authentication MIB 
2665  Ethernet-like Interfaces MIB 
2674  Extended Bridge MIB
2787  VRRP MIB 
2819  RMON MIB 
  
(groups 1, 2, 3, 9)
2863  Interfaces MIB
2865  RADIUS
3273  RMON High Capacity MIB
3376  IGMPv3
3416  SNMPv2
3418  SNMP MIB
3434  RMON High Capacity 
  
Alarm MIB
3580  802.1X with RADIUS
5060  PIM MIB
ANSI/TIA-1057 LLDP-MED MIB
draft-grant-tacacs-02
  
TACACS+
draft-ietf-idr-bgp4-mib-06
  
BGP MIBv1
IEEE 802.1AB
  
LLDP MIB, LLDP DOT1
  
MIB, LLDP DOT3 MIB
ruzin-mstp-mib-02
  
MSTP MIB (traps)
sFlow.org sFlowv5
sFlow.org sFlowv5 MIB (version 
1.3)
FORCE10-BGP4-V2-MIB
FORCE10-CS-CHASSIS-MIB
FORCE10-IF-EXTENSION-MIB
FORCE10-LINKAGG-MIB
FORCE10-COPY-CONFIG-MIB
FORCE10-MON-MIB
FORCE10-PRODUCTS-MIB
FORCE10-SMI
FORCE10-SYSTEM-COMPONENT-
MIB
FORCE10-TC-MIB
FORCE10-TRAP-ALARM-MIB
Network management
Regulatory compliance
Safety
UL/CSA 60950-1
EN 60950-1
IEC 60950-1, Including all National Deviations and Group Differences
EN 60825-1 Safety of Laser Products Part 1: 
 
Equipment Classification Requirements and User’s Guide
EN 60825-2 Safety of Laser Products Part 2: 
 
Safety of Optical Fibre Communication Systems
FDA Regulation 21 CFR 1040.10 and 1040.11
Emissions
A
ustralia/New Zealand: AS/NZS CISPR 22: Class A
Canada: ICES-003, Issue-4, Class A
Europe: EN 55022 (CISPR 22), Class A
Japan: VCCI Class A
USA: FCC CFR 47 Part 15, Subpart B, Class A
Immunity
EN 300 386: EMC for Network Equipment
EN 55024
EN 61000-3-2: Harmonic Current Emissions
EN 61000-3-3:Voltage Fluctuations and Flicker
EN 61000-4-2: ESD
EN 61000-4-3: Radiated Immunity
EN 61000-4-4: EFT
EN 61000-4-5: Surge
EN 61000-4-6: Low Frequency Conducted Immunity
RoHS  
 
All C-Series components are EU RoHS compliant
Certifications 
TAA (Trade Agreement Act) compliant models also available
 
 
1058  RIPv1
2453  RIPv2
RIP
OSPF
1587  NSSA
2328  OSPFv2
2370  Opaque LSA
2740  OSPFv3
     3623 
Graceful Restart
  4222 
Prioritization and
   
 
Congestion Avoidance