Thermal Specifications and Design Considerations
5
Thermal Specifications and
Design Considerations
5.1
Processor Thermal Specifications
The processor requires a thermal solution to maintain temperatures within the
operating limits as set forth in
. Any attempt to operate the processor
outside these operating limits may result in permanent damage to the processor and
potentially other components within the system. As processor technology changes,
thermal management becomes increasingly crucial when building computer systems.
Maintaining the proper thermal environment is key to reliable, long-term system
operation.
A complete thermal solution includes both component and system level thermal
management features. Component level thermal solutions can include active or passive
heatsinks attached to the processor Integrated Heat Spreader (IHS). Typical system
level thermal solutions may consist of system fans combined with ducting and venting.
For more information on designing a component level thermal solution, refer to the
Intel
®
Pentium
®
D Processor, Intel
®
Pentium
®
Processor Extreme Edition, and Intel
®
Pentium
®
4 Processor Thermal and Mechanical Design Guidelines.
Note:
The boxed processor will ship with a component thermal solution. Refer to
for details on the boxed processor.
5.1.1
Thermal Specifications
To allow for the optimal operation and long-term reliability of Intel processor-based
systems, the system/processor thermal solution should be designed such that the
processor remains within the minimum and maximum case temperature (T
C
)
specifications when operating at or below the Thermal Design Power (TDP) value listed
. Thermal solutions not designed to provide this level of
thermal capability may affect the long-term reliability of the processor and system. For
more details on thermal solution design, please refer to the Intel
®
Pentium
®
D
Processor, Intel
®
Pentium
®
Processor Extreme Edition, and Intel
®
Pentium
®
4
Processor Thermal and Mechanical Design Guidelines.
The processor uses a methodology for managing processor temperatures that is
intended to support acoustic noise reduction through fan speed control. Selection of the
appropriate fan speed will be based on the temperature reported by the processor’s
Thermal Diode. If the diode temperature is greater than or equal to T
CONTROL
, then the
processor case temperature must remain at or below the temperature as specified by
the thermal profile. If the diode temperature is less than T
CONTROL
then the case
temperature is permitted to exceed the thermal profile, but the diode temperature
must remain at or below T
CONTROL
. Systems that implement fan speed control must be
designed to take these conditions in to account. Systems that do not alter the fan
speed only need to ensure the case temperature meets the thermal profile
specifications.
To determine a processor's case temperature specification based on the thermal profile,
it is necessary to accurately measure processor power dissipation. Intel has developed
a methodology for accurate power measurement that correlates to Intel test
temperature and voltage conditions. Refer to the Intel
®
Pentium
®
D Processor, Intel
®