Enermax EMP600AGT User Manual

Page of 4
©
 
2015 ENERMAX TECHNOLOGY CORPORATION. All rights reserved. Specifications are subject to change without notice. Content of delivery might differ 
in different areas or from illustrations. Some trademarks may be claimed as the property of others. 
www.enermax.com
Jan. 2015
+3.3V
+5V
+12V
+3.3V
+5V
+12V
Over Current 
Protection
Over Voltage 
Protection
22-35A
22-35A
33-47A
22-35A
22-35A
41-55A 
22-35A
22-35A 
49-63A
24-35A 
24-35A 
57-71A 
Over Power 
Protection
Short Circuit 
Protection 
Specifications
EMP400AGT
EMP400AGT
AC Input
Input Voltage
Input Current
+3.3V
+5V
+12V
-12V
+5Vsb
200V-240V, 47-63Hz, Active PFC
3A
4A
4.5A
5A
EMP500AGT
EMP500AGT
EMP600AGT
EMP600AGT
EMP700AGT
EMP700AGT
DC Output
16A
16A
30A
0.3A
2.5A
18A
18A
38A
0.3A
2.5A
20A
20A
46A
0.3A
2.5A
22A
22A
54A
0.3A
2.5A
100W
110W
120W
130W
360W
3.6W
12.5W
456W
3.6W
12.5W
552W
3.6W
12.5W
648W
3.6W
12.5W
Total Power
Peak Power*
Model No.
Model No.
400W
440W
550W
660W
770W
500W
600W
700W
Cable&Connector
Certifications & Standards
Model No.
24P Mainboard 4+4P (8P) CPU
SATA
4P Molex
FDD
6+2P (8P) PCI-E
EMP400AGT
EMP500AGT
EMP600AGT
EMP700AGT
1 (1 x 50cm)
1(1 x 50cm)
1(1 x 50cm)
1(1 x 50cm)
1(1 x 60cm)
1(1 x 60cm)
1(1 x 60cm)
1(1 x 60cm)
2(1 x 45/60cm)
2(1 x 45/60cm)
2(1 x 45/60cm)
3(1 x 45cm,1x 45/60cm)
5
5
6
8
4
4
4
4
1
1
1
1
Protection
 
                                        4.5V
 
                                        7.0V
 
                                       15.6V
115% - 150% of rated max load
Activated when short-circuited
*Maximum range 180-264V   *Peak power may last up to 60 seconds