Electrical Specifications
70
Datasheet, Volume 1
7.9
DC Specifications
The processor DC specifications in this section are defined at the processor 
pads, unless noted otherwise.
 See 
 for the processor land listings and 
 for signal definitions. Voltage and current specifications are detailed in 
 an
. For platform planning, refer to 
 that provides V
CC
 
static and transient tolerances. This same information is presented graphically in 
The DC specifications for the DDR3 signals are listed in 
 Control Sideband and 
Test Access Port (TAP) are listed in 
 list the DC specifications for the processor and are valid 
only while meeting the thermal specifications (as specified in the processor Thermal 
and Mechanical Specifications and Guidelines), clock frequency, and input voltages. 
Care should be taken to read all notes associated with each parameter. 
7.9.1
Voltage and Current Specifications
Notes:
1.
Each processor is programmed with a maximum valid voltage identification value (VID) that is set at 
manufacturing and cannot be altered. Individual maximum VID values are calibrated during manufacturing 
such that two processors at the same frequency may have different settings within the VID range. Note 
that this differs from the VID employed by the processor during a power management event (Adaptive 
Thermal Monitor, Enhanced Intel SpeedStep Technology, or Low Power States).
2.
The voltage specification requirements are measured across VCC_SENSE and VSS_SENSE lands at the 
socket with a 100-MHz bandwidth oscilloscope, 1.5 pF maximum probe capacitance, and 1-M minimum 
impedance. The maximum length of ground wire on the probe should be less than 5 mm. Ensure external 
noise from the system is not coupled into the oscilloscope probe. 
3.
Refer to 
 and 
 for the minimum, typical, and maximum V
CC
 allowed for a given current. 
The processor should not be subjected to any V
CC
 and I
CC 
combination wherein V
CC
 exceeds V
CC_MAX
 for a 
given current.
4.
I
CC_MAX
 specification is based on the V
CC_MAX
 loadline. Refer to 
 for details.
Table 7-5.
Processor Core Active and Idle Mode DC Voltage and Current Specifications 
Symbol
Parameter
Min
Typ
Max
Unit
Note
VID
VID Range
0.6500
1.4000
V
V
CC
V
CC
 for processor core
See 
V
1,  2,  3
V
CC,BOOT
Default V
CC 
voltage for initial power up
1.10
V
I
CC
Processor 
Number
X3480
X3470
X3460
X3450
X3440
X3430
For Intel Xeon processor 3400 
series with 95 W TDP
3.06 GHz
2.93 GHz
2.80 GHz
2.66 GHz
2.53 GHz
2.40 GHz
110
110
110
110
110
110
A
4
I
CC
Processor 
Number
L3426
For Intel Xeon processor 3400 
series with 45 W TDP
1.86 GHz
55
A
4
I
CC_TDC
Sustained ICC; recommended design target 
for Intel Xeon processor 3400 series with 
95 W TDP
90
A
I
CC_TDC
2009A Sustained I
CC
; recommended design 
target for Intel Xeon processor 3400 series 
with 45 W TDP
45
A