Adaptec 6805Q 2270700-R User Manual

Product codes
2270700-R
Page of 155
Appendix G: Technical Specifications
149
Environmental Specifications
Note: 
Adaptec RAID controllers require adequate airflow to operate reliably. The recommended 
airflow is 200 LFM (linear feet per minute). Forced airflow is recommended.
Note: 
Ambient temperature is measured 1” from RAID processor.
DC Power Requirements
Current Requirements  
Ambient temperature with forced airflow
0 °C to 55 °
 
Ambient temperature with Battery Backup Unit (BBU)
1
1
BBU is not supported on all controllers. See 
 for more information.
0 °C to 40 °
 
C
Relative humidity
10% to 90%
, noncondensing
Altitude
Up to 3,000 meters
Bus Type
Description
Requirements
PCIe
Ripple and noise
50 mV peak-to-peak (max)
PCIe
DC Voltage
3.3 V ± 9%, 12 V ± 8%
Adaptec Model
Typical Current
Adaptec RAID 5085
0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC
Adaptec RAID 5805/5805Q
0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC
Adaptec RAID 5405
0.45A @ 3.3 VDC; 0.94A @ 12.0 VDC
Adaptec RAID 5445
0.45A @ 3.3 VDC; 1.0A @ 12.0 VDC
Adaptec RAID 5805Z/5805ZQ
0.39 A @ 3.3 VDC; 1.21 A @ 12.0 VDC
Adaptec RAID 5405Z
0.38 A @ 3.3 VDC; 1.18 A @ 12.0 VDC
Adaptec RAID 5445Z
0.40 A @ 3.3 VDC; 1.24 A @ 12.0 VDC
Adaptec RAID 51245
0.47A @ 3.3 VDC; 1.68A @ 12.0 VDC
Adaptec RAID 51645
0.47A @ 3.3 VDC; 1.72A @ 12.0 VDC
Adaptec RAID 52445
0.47A @ 3.3 VDC; 1.78A @ 12.0 VDC
Adaptec RAID 2045
0.43A @ 3.3 VDC; 0.83A @ 12.0 VDC
Adaptec RAID 2405/2405Q
0.43A @ 3.3 VDC; 0.83A @ 12.0 VDC
Adaptec RAID 2805
0.5A @ 3.3 VDC; 0.95A @ 12.0 VDC 
Adaptec RAID 6405
0.17A @ 3.3 VDC; 1.25A @ 12.0 VDC
Adaptec RAID 6445
0.17A @ 3.3 VDC; 1.25A @ 12.0 VDC
Adaptec RAID 6805/6805Q
0.17A @ 3.3 VDC; 1.25A @ 12.0 VDC
Adaptec RAID 6405E
0.11A @ 3.3 VDC; 0.75A @ 12.0 VDC
Adaptec RAID 6805E
0.125A @ 3.3 VDC; 0.80A @ 12.0 VDC
Adaptec RAID 6405T
0.125A @ 3.3 VDC; 0.97A @ 12.0 VDC
Adaptec RAID 6805T/6805TQ
0.125A @ 3.3 VDC; 0.97A @ 12.0 VDC