Panasonic KIT-XE7-LKE User Manual

Page of 16
20
1) EER and COP classification is at 230 V in accordance with EU directive 2002/31/EC.
2) The annual consumption is calculated by multiplying the input power at 230 V by an avarage of 500 hours per year in cooling mode.
3) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 0,8 meters below the 
unit. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification.
4) Add 70 mm for piping port.
5) When installing the outdoor unit at a higher position than the indoor unit.
GLOBAL REMARKS 
Rating conditions 
Cooling 
Heating
 
Inside air temperature 
27ºC DB / 19ºC WB 
20ºC DB
 
Outside air temperature 
35ºC DB / 24ºC WB 
7ºC DB / 6ºC WB
DB: Dry Bulb; WB: Wet Bulb
This model is not suitable to use in heating mode below -5ºC with continuous operation (24h operation).
Connectivity restriction: JKE units are not compatible with LKE units.
WALL MOUNTED ETHEREA // INVERTER+ // SILVER
NEW ETHEREA WITH ECO PATROL, MORE EFFICIENT, MORE COMFORT, MORE DESIGN, MORE HEALTHY AIR
Eco Patrol’s sensor technology uses factors such as speed, frequency and temperature to determine the human 
activity level in the room for maximum comfort and maximum savings. With Eco Patrol, you can save up to 30%. 
Furthermore, Etherea is more efficient than ever with 64% less consumption for the non Inverter model on 
heat pump mode, and can reach 71% total savings when used with Eco Patrol. More efficiency for bigger 
savings!
Etherea has an advanced air purifying system with the new Patrol Sensor to detect and eliminate 
contaminants.
Etherea is also able to prevent rapid decreases in room humidity with the new mild dry cooling system which 
increases comfort, especially when sleeping with the air conditioning running.
WALL MOUNTED ETHEREA // INVERTER+ // SILVER
Kit
KIT-XE7-LKE
KIT-XE9-LKE
KIT-XE12-LKE
KIT-XE15-LKE
Indoor
CS-XE7LKEW
CS-XE9LKEW
CS-XE12LKEW
CS-XE15LKEW
Outdoor
CU-E7LKE
CU-E9LKE
CU-E12LKE
CU-E15LKE
Cooling capacity
Nominal (Min - Max)
kW
2.05 (0.70-2.40)
2.50 (0.80-3.00)
3.50 (0.80-4.00)
4.20 (0.80-5.00)
Nominal (Min - Max)
kCal/h
1,760 (600-2,060)
2,150 (690-2,580)
3,010 (690-3,440)
3,610 (690-4,300)
EER 
1)
Nominal (Min - Max)
Energy Saving Classification
4.36 (4.12-4.14) 
A
4.67 (4.57-4.11) 
A
4.07 (4.32-3.54) 
A
3.33 (4.10-3.18) 
A
Power input Cooling
Nominal (Min - Max)
kW
0.47 (0.17-0.58)
0.535 (0.175-0.730)
0.860 (0.185-1.130)
1.26 (0.195-1.570)
Heating capacity
Nominal (Min - Max)
kW
2.80 (0.70-4.00)
3.40 (0.80-5.00)
4.00 (0.80-6.00)
5.30 (0.80-6.80)
Nominal (Min - Max)
kCal/h
2,410 (600-3,440)
2,920 (690-4,300)
3,440 (690-5,160)
4,560 (690-5850)
Heating capacity at -7°C
Nominal
kW
2.35
2.88
3.46
3.94
COP 
1)
Nominal (Min - Max)
Energy Saving Classification
4.41 (4.38-3.92) 
A
4.63 (4.85-3.85) 
A
4.21 (4.57-3.51) 
A
3.68 (4.32-3.51) 
A
Power input Heating
Nominal (Min - Max)
kW
0.635 (0.16-1.02)
0.735 (0.165-1.30)
0.950 (0.175-1.71)
1.44 (0.185-1.940)
Annual Energy Consumption 
2)
kWh
235
268
430
630
Indoor unit
Air Volume
Cooling / Heating
m³/h
654 / 684
678 / 702
750 / 768
750 / 804
Moisture removal volume
l/h
1.3
1.5
2.0
2.4
Sound pressure Level 
3)
Cooling (Hi / Lo / S-Lo)
dB(A)
37 / 24 / 20
39 / 25 / 20
42 / 28 / 20
43 / 31 / 25
Heating (Hi / Lo / S-Lo)
dB(A)
38 / 25 / 20
40 / 27 / 20
42 / 33 / 20
43 / 35 / 29
Sound power Level
Cooling (Hi)
dB
53
55
58
59
Heating (Hi)
dB
54
56
58
59
Dimensions
H x W x D
mm
290 x 870 x 204
290 x 870 x 204
290 x 870 x 204
290 x 870 x 204
Net weight
kg
9
9
9
9
Air purifier filter
Patrol + E-ion
Patrol + E-ion
Patrol + E-ion
Patrol + E-ion
Outdoor unit
Power source
V
230
230
230
230
Connection
mm²
4 x 1.5
4 x 1.5
4 x 1.5
4 x 1.5
Current Cooling
Nominal
A
2.2
2.5
3.9
5.7
Current Heating
Nominal
A
3.0
3.4
4.4
6.6
Max. current
A
4.7
5.8
7.8
9.0
Air Volume
Cooling / Heating
m³/h
2,034 / 2,034
1,788 / 1,788
1,860 / 1,860
1,884 / 1,884
Sound pressure Level 
3)
Cooling (Hi)
dB(A)
45
46
48
49
Heating (Hi)
dB(A)
46
47
50
51
Sound power Level
Cooling (Hi)
dB
60
61
63
64
Heating (Hi)
dB
61
62
65
66
Dimensions 
4)
H x W x D
mm
540 x 780 x 289
540 x 780 x 289
540 x 780 x 289
540 x 780 x 289
Net weight
kg
33
34
34
34
Piping connections
Liquid pipe
inch (mm)
1/4" (6.35)
1/4" (6.35)
1/4" (6.35)
1/4" (6.35)
Gas pipe
inch (mm)
3/8" (9.52) 
3/8" (9.52) 
3/8" (9.52) 
1/2" (12.70)
Refrigerant Loading
R410A
kg
0.830
0.950
0.980
1.01
Elevation difference (in/out) 
5)
Max
m
15
15
15
15
Piping length
Min / Max
m
3-15
3-15
3-15
3-15
Piping length without refrigerant 
increase
Max
m
7.5
7.5
7.5
7.5
Additional gas
g/m
20
20
20
20
Operating range 
3)
Cooling Min / Max
°C
+5 / +43
+5 / +43
+5 / +43
+5 / +43
Heating Min / Max
°C
-5 / +24
-5 / +24
-5 / +24
-5 / +24
Maintains a Relative Humidity up to 10% 
higher than cooling operation. Ideal when 
sleeping with the air conditioner on.