Platform Management Functional Overview 
Intel® Server Board S1400SP TPS 
 
 
Revision 1.0 
Intel order number G64248-001 
 
52 
Source 
External Signal Name or  
Internal Subsystem 
Capabilities 
Power state retention 
Implemented by means of BMC 
internal logic 
Turns power on when AC power returns 
Chipset 
Sleep S4/S5 signal (same as 
POWER_ON
Turns power on or off 
CPU Thermal 
CPU Thermtrip 
Turns power off 
WOL(Wake On LAN) 
LAN 
Turns power on 
 
6.6  BMC Watchdog 
The BMC FW is increasingly called upon to perform system functions that are time-critical in 
that failure to provide these functions in a timely manner can result in system or component 
damage. Intel
®
 S1400/S1600/S2400/S2600/S4600 Server Platforms introduce a BMC watchdog 
feature to provide a safe-guard against this scenario by providing an automatic recovery 
mechanism. It also can provide automatic recovery of functionality that has failed due to a fatal 
FW defect triggered by a rare sequence of events or a BMC hang due to some type of HW 
glitch (for example, power). 
 
This feature is comprised of a set of capabilities whose purpose is to detect misbehaving 
subsections of BMC firmware, the BMC CPU itself, or HW subsystems of the BMC component, 
and to take appropriate action to restore proper operation. The action taken is dependent on the 
nature of the detected failure and may result in a restart of the BMC CPU, one or more BMC 
HW subsystems, or a restart of malfunctioning FW subsystems. 
 
The BMC watchdog feature will only allow up to three resets of the BMC CPU (such as HW 
reset) or entire FW stack (such as a SW reset) before giving up and remaining in the uBOOT 
code. This count is cleared upon cycling of power to the BMC or upon continuous operation of 
the BMC without a watchdog-generated reset occurring for a period of > 30 minutes. The BMC 
FW logs a SEL event indicating that a watchdog-generated BMC reset (either soft or hard reset) 
has occurred. This event may be logged after the actual reset has occurred. Refer sensor 
section for details for the related sensor definition. The BMC will also indicate a degraded 
system status on the Front Panel Status LED after an BMC HW reset or FW stack reset. This 
state (which follows the state of the associated sensor) will be cleared upon system reset or (AC 
or DC) power cycle. 
 
Note: A reset of the BMC may result in the following system degradations that will require a 
system reset or power cycle to correct: 
1.  Timeout value for the rotation period can be set using this parameter. Potentially, there 
will be incorrect ACPI Power State reported by the BMC. 
2.  Reversion of temporary test modes for the BMC back to normal operational modes. 
3.  FP status LED and DIMM fault LEDs may not reflect BIOS detected errors. 
 
6.7  Fault Resilient Booting (FRB) 
Fault resilient booting (FRB) is a set of BIOS and BMC algorithms and hardware support that 
allow a multiprocessor system to boot even if the bootstrap processor (BSP) fails. Only FRB2 is 
supported using watchdog timer commands.