Intel S1400SP4 DBS1400SP4 User Manual

Product codes
DBS1400SP4
Page of 159
Platform Management Functional Overview 
Intel® Server Board S1400SP TPS 
 
 
Revision 1.0 
Intel order number G64248-001 
 
60 
See the Intelligent Platform Management Interface Specification Second Generation v2.0 for 
details about the IPMI-over-LAN protocol. 
Run-time determination of LAN channel capabilities can be determined by both standard IPMI 
defined mechanisms. 
6.12.3.1 
RMCP/ASF Messaging 
The BMC supports RMCP ping discovery in which the BMC responds with a pong message to 
an RMCP/ASF ping request. This is implemented per the Intelligent Platform Management 
Interface Specification Second Generation v2.0

 
6.12.3.2 
BMC LAN Channels 
The BMC supports three RMII/RGMII ports that can be used for communicating with Ethernet 
devices. Two ports are used for communication with the on-board NICs and one is used for 
communication with an Ethernet PHY located on an optional RMM4 add-in module. 
6.12.3.2.1  Baseboard NICs 
The on-board Ethernet controller provides support for a Network Controller Sideband Interface 
(NC-SI) manageability interface. This provides a sideband high-speed connection for 
manageability traffic to the BMC while still allowing for a simultaneous host access to the OS if 
desired.  
The NC-SI is a DMTF industry standard protocol for the side band management LAN interface. 
This protocol provides a fast multi-drop interface for management traffic.  
The baseboard NIC(s) are connected to a single BMC RMII/RGMII port that is configured for 
RMII operation. The NC-SI protocol is used for this connection and provides a 100 Mb/s full-
duplex multi-drop interface which allows multiple NICs to be connected to the BMC. The 
physical layer is based upon RMII, however RMII is a point-to-point bus whereas NC-SI allows 1 
master and up to 4 slaves. The logical layer (configuration commands) is incompatible with 
RMII.  
The server board will provide support for a dedicated management channel that can be 
configured to be hidden from the host and only used by the BMC. This mode of operation is 
configured from a BIOS setup option.  
6.12.3.2.2  Dedicated Management Channel 
An additional LAN channel dedicated to BMC usage and not available to host SW is supported 
from an optional RMM4 add-in card. There is only a PHY device present on the RMM4 add-in 
card. The BMC has a built-in MAC module that uses the RGMII interface to link with the card’s 
PHY. Therefore, for this dedicated management interface, the PHY and MAC are located in 
different devices.  
 
The PHY on the RMM4 connects to the BMC’s other RMII/RGMII interface (that is, the one that 
is not connected to the baseboard NICs). This BMC port is configured for RGMII usage. 
In addition to the use of an RMM4 add-in card for a dedicated management channel, on 