Intel® Server Board S1400SP TPS 
On-board Connector/Header Overview 
Revision 1.0 
 
 
Intel order number G64248-001 
85 
transfer rates of up to 3Gb/s. The connector labeled “SCU_1” is only enabled when an optional 
8-port SAS or SATA Intel
®
 RAID C600 Upgrade Key is installed. See Table 7 for a complete list 
of supported storage upgrade keys.  
 
“SATA_2-5” connector supports up to four SATA ports capable of transfer rates of up to 3Gb/s. 
The following tables provide the pin-out for each connector. 
Table 32. Multiport SAS/SATA Connector Pin-out 
Signal Description 
Pin# 
Pin#  
Signal Description 
GROUND 
A1 
B1 
GROUND 
SAS0_RX_C_DP 
A2 
B2 
SAS0_TX_C_DP 
SAS0_RX_C_DN 
A3 
B3 
SAS0_TX_C_DN 
GROUND 
A4 
B4 
GROUND 
SAS1_RX_C_DP 
A5 
B5 
SAS1_TX_C_DP 
SAS1_RX_C_DN 
A6 
B6 
SAS1_TX_C_DN 
GROUND 
A7 
B7 
GROUND 
TP_SAS1_BACKPLANE_TYPE 
A8 
B8 
SGPIO_SAS1_CLOCK 
GROUND 
A9 
B9 
SGPIO_SAS1_LOAD 
SGPIO_SAS1_DATAOUT 
A10 
B10 
GROUND 
SGPIO_SAS1_DATAIN 
A11 
B11 
PD_SAS1_CONTROLLER_TYPE 
GROUND 
A12 
B12 
GROUND 
SAS2_RX_C_DP 
A13 
B13 
SAS2_TX_C_DP 
SAS2_RX_C_DN 
A14 
B14 
SAS2_TX_C_DN 
GROUND 
A15 
B15 
GROUND 
SAS3_RX_C_DP 
A16 
B16 
SAS3_TX_C_DP 
SAS3_RX_C_DN 
A17 
B17 
SAS3_TX_C_DN 
GROUND 
A18 
B18 
GROUND 
GROUND 
MTH1 
MTH5 
GROUND 
GROUND 
MTH2 
MTH6 
GROUND 
GROUND 
MTH3 
MTH7 
GROUND 
GROUND 
MTH4 
MTH8 
GROUND 
 
8.5  Fan Connectors 
The server board provides two SSI-compliant 4-pin and five 10-pin fan headers to use as CPU 
and I/O cooling fans. Each connector is monitored and controlled by on-board platform 
management.  
The following table provides the pin-out for all fan connectors. 
  One 4-pin fan header is designated as processor cooling fans:  
o
  CPU FAN 
  One 4-pin fan header is designated as rear system fan: 
o
  SYS FAN_6 
  Five 10-pin fan headers are designated as redundant system fans:  
o
  SYS FAN_1 
o
  SYS FAN_2 
o
  SYS FAN_3 
o
  SYS FAN_4 
o
  SYS FAN_5