4.999.112.593
Installation manual Integral 5 D/E easy
Basic module BND (control module for I5 D easy)
Short description of BND (control module for I5 D easy)
Short description of BND
Function
Control module for I5 easy. 1x per system required
Slots
There are 4 slots on the BND
Slot 2 (slot address 1)
Slot 4 (slot address 3)
Slot 6 (slot address 5)
Slot 8 (slot address 7)
Plug-in 
modules
2-slot and / or 4-slot plug-in module (IOM and LAN)
 
Single 1-slot plug-in module "DIA" (IOM)
IOM
IOM is a connection local to BND, which is available at all slots. IOM modules can be driven through this connection. IOM 
modules have no switching matrix control of their own and are generally controlled only by the BND through the IOM connection.
For an IOM extension using EXE modules, 2 sockets EXP1 and EXP2 are provided. Each socket drives 8 x 2B channels 
(16 B channels) for further applications
LAN
LAN is a 128 B channel connection, which is available at all slots. LAN modules that are connected "draw" this connection 
from their total of available B channels.
LAN modules are intelligent plug-in modules with their own switching matrix control
The LAN connection is not brought out from the BND for further applications
Note
4-slot plug-in module at slots 4 and 8
BND has a cold-start switch, which is accessed through a hole in the casing. There is no "cold-start plug".
If pressed for less than 5 sec: Reset, warm start. If pressed for more than 5 sec: Cold start
Left hand LED, see "LEDs on the BNE" on the back
Right hand LED, see "LEDs on the BNE" on the back
V.24 plug-in module cannot be inserted into slot 2, the V.24 connection has its own port on the basic module casing
The BND can be powered using a separate plug-in mains unit (Vin) or it can be fed from another EXE module (Vin). See plug-in mains unit
Max. 1 x CV1 and max. 1 x T8S on a BND. 1 x CV1 plus 1 x T8S permissible on a BND.