Panasonic CS-UE18QKE + CU-UE18QKE KIT-UE18-QKE User Manual

Product codes
KIT-UE18-QKE
Page of 92
Possible
to use on
R22 pipings
R22 RENEWAL
Prevention
allergen filter
ANTI BACTERIAL 
FILTER
6,10 A++
SEER
SEASONAL ENERGY 
EFFICIENCY RATIO
SUPER QUIET
Silent air
22 dB
4,00 A+
SCOP
SEASONAL COEFFICIENT  
OF PERFORMANCE
RE Inverter models are powerful and efficient, with an outstanding energy ranking of A++/A+, unique in the 
market! The RE works up to an outdoor temperature of -15°C in heating mode and -10°C up a outdoor 
temperature of -15°C in heating and -10 in cooling and still with a high efficiency and capacity! Furthermore, 
the annual energy consumption has never been so low.
RE has a unique Anti Bacterial Filter in order to enjoy the best quality air, without viruses, mould or bacteria.
WALL MOUNTED RE TYPE
STANDARD INVERTER
SEER and SCOP: For KIT-RE9-QKE and KIT-RE12-QKE. SUPER QUIET: For RE9 and RE12.
E
nergy 
saving
Kit
KIT-RE9-QKE
KIT-RE12-QKE
KIT-RE15-QKE
KIT-RE18-QKE
KIT-RE24-QKE
Indoor
CS-RE9QKE
CS-RE12QKE
CS-RE15QKE
CS-RE18QKE
CS-RE24QKE
Outdoor
CU-RE9QKE
CU-RE12QKE
CU-RE15QKE
CU-RE18QKE
CU-RE24QKE
Cooling capacity
Nominal (Min - Max)
kW
2,50 (0,85 - 3,00)
3,50 (0,85 - 3,90)
4,20 (0,85 - 4,60)
5,00 (0,98 - 6,00)
6,80 (0,98 - 8,10)
Nominal (Min - Max)
kCal/h
2.150 (730 - 2.580)
3.010 (730 - 3.350)
3.610 (730 - 3.960)
4.300 (840 - 5.160)
5.850 (840 - 6.970)
SEER
Nominal
Energy Saving 6,10 i
6,10 i
5,60 h
6,70 i
6,00 h
Pdesign (cooling)
kW
2,5
3,5
4,2
5,0
6,8
Power input cooling
Nominal (Min - Max)
kW
0,670 (0,250 - 0,950)
1,000 (0,255 - 1,190)
1,260 (0,265 - 1,650)
1,470 (0,280 - 2,030)
2,100 (0,380 - 2,670)
Annual electricity consumption (cooling) 
1)
kWh/a
143
201
263
261
397
Heating capacity
Nominal (Min - Max)
kW
3,30 (0,80 - 4,10)
4,00 (0,80 - 5,10)
5,00 (0,80 - 6,80)
5,80 (0,98 - 8,00)
8,60 (0,98 - 9,90)
Nominal (Min - Max)
kCal/h
2.840 (690 - 3.530)
3.440 (690 - 4.390)
4.300 (690 - 5.850)
4.990 (840 - 6.880)
7.400 (840 - 8.510)
Heating capacity at -7°C
Nominal
kW
2,7
3,30
3,9
4,98
6,13
SCOP
Nominal
Energy Saving 4,00 h
4,00 h
3,80 a
4,10 h
3,80 a
Pdesign at -10°C
kW
2,4
2,8
3,6
4,4
5,5
Power input heating
Nominal (Min - Max)
kW
0,800 (0,195 - 1,130)
1,050 (0,200 - 1,420)
1,350 (0,200 - 2,050)
1,540 (0,340 - 2,600)
2,610 (0,450 - 3,130)
Annual electricity consumption (heating) 
1)
kWh/a
840
980
1.326
1.502
2.026
Indoor Unit
Power source
V
230
230
230
230
230
Recommended fuse
A
16
16
16
16
16
Recommended power cable section
mm²
1,5
1,5
2,5
2,5
2,5
Connection (indoor/outdoor)
mm²
4 x 1,5
4 x 1,5
4 x 1,5
4 x 1,5
4 x 1,5
Current (Nominal)
Cooling / Heating
A
2,95 / 3,55
4,00 / 4,60
5,60 / 6,00
6,60 / 6,90
9,60 / 11,70
Maximum current
A
5,0
6,2
9,2
11,4
14,5
Air volume
Cooling / Heating
m³/h
702 / 768
738 / 768
750 / 804
978 / 1.074
1.104 / 1.170
Moisture removal volume
l/h
1,5
2
2,4
2,8
3,9
Sound pressure level 
2)
Cooling (Hi / Lo / Q-Lo) dB(A)
41 / 26 / 22
42 / 30 / 22
44 / 31 / 29
44 / 37 / -
47 / 38 / -
Heating (Hi / Lo / Q-Lo) dB(A)
41 / 27 / 25
42 / 33 / 25
44 / 35 / 28
44 / 37 / -
47 / 38 / -
Sound power level
Cooling (Hi)
dB
57
58
60
60
63
Heating (Hi)
dB
57
58
60
60
63
Dimensions
H x W x D
mm
290 x 870 x 214
290 x 870 x 214
290 x 870 x 214
290 x 1.070 x 240
290 x 1.070 x 240
Net weight
kg
9
9
9
12
12
Air purifier filter
Anti Bacterial Filter
Anti Bacterial Filter
Anti Bacterial Filter
Anti Bacterial Filter
Anti Bacterial Filter
Silver decoration sheet
Yes
Yes
Yes
Yes
Yes
Outdoor Unit
Air volume
Cooling / Heating
m³/h
1.788 / 1.740
1.998 / 1.998
1.998 / 1.998
2.064 / 2.040
3.012 / 3.012
Sound pressure level 
2)
Cooling (Hi)
dB(A)
47
48
49
47
52
Heating (Hi)
dB(A)
48
50
51
47
52
Sound power level
Cooling (Hi)
dB
62
63
64
61
66
Heating (Hi)
dB
63
65
66
61
66
Dimensions 
3)
H x W x D
mm
542 x 780 x 289
619 x 824 x 299
619 x 824 x 299
695 x 875 320
795 x 875 x 320
Net weight
kg
33
34
34
46
67
Piping connections
Liquid / Gas pipe
inch (mm)
1/4 (6,35) / 3/8 (9,52) 
1/4 (6,35) / 3/8 (9,52) 
1/4 (6,35) / 1/2 (12,70)
1/4 (6,35) / 1/2 (12,70)
1/4 (6,35) / 5/8 (15,88)
Refrigerant loading
R410A
kg
0,97
1,02
1,02
1,22
1,80
Elevation difference (in/out)
Max
m
15
15
15
15
20
Piping length
Min / Max
m
3 / 15
3 / 15
3 / 15
3 / 20
3 / 30
Precharge length
Max
m
7,5
7,5
7,5
7,5
10,0
Additional charge
g/m
20
20
20
20
30
Operating range
Cooling Min / Max
°C
-10 / +43
-10 / +43
-10 / +43
-10 / +43
-10 / +43
Heating Min / Max
°C
-15 / +24
-15 / +24
-15 / +24
-15 / +24
-15 / +24
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb)
Connectivity restriction: JKE units are not compatible with QKE units.
1) The annual energy consumption is calculated in accordance with the ErP directive. 2) The Sound pressure level of the units shows the value measured of a position 1 metre in front of the main body and 0,8 m below the unit. The sound pressure is measured in 
accordance with Eurovent 6/C/006-97 specification. Q-Lo: The lowest fan speed. Lo: The second lowest fan speed (the lowest fan speed for RE18/24). 3) Add 70 mm for piping port.
Specifications subject to change without notice.
For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu
5 year
compressor
warranty
46