Lappkabel 0015305, ÖLFLEX® 150 QUATTRO Control Data Cable, 5 x 1.5 mm², Grey Sheath 0015305 Data Sheet

Product codes
0015305
Page of 2
DATA SHEET 
0015003 
 
ÖLFLEX
®
 150 QUATTRO 
valid from : 
15.10.2009
 
 
 
Originator: R. Krämer / TE-K
 
approved: H. Schillinger / TE-K 
Document: 
DB0015003EN 
page 1 of 2 
All deviations from this specification are subject to explicit consent of U.I.LAPP GmbH. All rights reserved acc. to DIN 34.  
No.: 0019/0408
 
 
Application 
 
ÖLFLEX
®
 150 QUATTRO cables are oil resistant power and control cables for occasional flexible use and fixed 
installation  for  medium  mechanical  stresses.  They  are  among  others  designed  for  use  in  dry,  damp  and  wet 
rooms.  Due  to  their  construction  and  the  composition  of material,  they  are  approved  in  accordance  with  Euro-
pean, US - American and Canadian standards. They are not designed for outdoor use.  
ÖLFLEX
®
 150 QUATTRO cables are increased oil resistant and at room temperature they are widely resistant to 
acids and alkali-resistant. They are suitable for free non-continuously recurring movement without tensile load or 
compulsory guidance.  
Application range:  
Plant engineering and construction, industrial machinery, air conditioning installations, machine tools. 
 
 
Design 
 
Design 
construction standard H05VV5-F acc. to HD 21.13S1 resp. VDE 0281-13,  
 
UL AWM Style 21098 or 2587, 
 
CSA AWM C22.2 No. 210-05 
 
Conductor 
fine wire strands of bare copper, acc. to IEC 60228 resp. VDE 0295, Class 5 
 
Core Insulation 
PVC compound TI2 in acc. to HD 21.1 resp. VDE 0281 part 1, 
 
UL-Class 43 / CSA 90 °C 
 
Core identification 
acc. to VDE 0293-1, with or without GN/YE ground conductor
 
 
black cores with white numbers 
 
acc. to DIN EN 50334 resp. VDE 0293-334 
 
Outer sheath 
PVC compound TM5 in acc. to HD 21.1 resp. VDE 0281 part 1, 
 
UL-Class 43 / CSA-90 °C 
 
 
Electrical properties 
 
Nominal voltage 
U
0
/U in acc. to HAR: 300 / 500 V 
 
U in acc. to UL/CSA: 600 V 
 
Test voltage 
3000 V AC 
 
 
Mechanical and thermal properties 
 
Min. bending radius 
occasional flexing:   
12,5 x cable diameter   
 
 
fixed installation: 
    4 x cable diameter 
 
Temperature range 
occasional flexing:   
 
 
in acc. to HAR: 
  -5 °C up to +70 °C max. conductor temp. 
 
in acc. to UL/CSA: 
  -5 °C up to +90 °C max. conductor temp. 
 
fixed installation:  
 
 
in acc. to HAR: 
-40 °C up to +70 °C max. conductor temp. 
 
in acc. to UL/CSA: 
-40 °C up to +90 °C max. conductor temp. 
 
 
Flammability 
HAR: In acc. with IEC 60332-1-2 resp. VDE 0482-332-1-2 
 
UL:    Vertical Flame Test in acc. to UL 1581 § 1061, UL VW-1, 
 
CSA: FT1