Lappkabel 2170001, Coax RG 174A/U Coaxial Cable, 50Ω Black Sheath 2170001 Data Sheet

Product codes
2170001
Page of 1
DATA SHEET 
2170001 
 
RG 174 A/U 
valid from : 
12. 06. 2008 
 
elaborated by:
 
TE-K:      A. Khan / H. Pfeffer  
Document: 
DB2170001EN 
page 1 of 1 
 
Nr.: 0019/0894 
  
 
Application  
 
Coaxial cable for radio- and computer systems as well as the entire field of commercial radio-frequency 
technology and electronics for low range transmissions, and with the small cable diameter, for application in 
narrow spaces. Cable design and electrical properties of RG 174 A/U according to MIL-C 17 F
Designation according to MIL-C 17 F :  M 17/119 – RG 174 
The cable is intended for limited flexible use and for static laying in dry and damp interiors and in open air. 
 
 
Design  
 
Inner conductor 
Stranded copper-clad steel wires, 26AWG, 0.14 mm
2
 (7 x 0.16), 0.48 ± 0.025mm ∅ 
Insulation 
PE (Solid polyethylene) 1.52 ±  0.08 mm∅; 
Outer conductor  
tinned copper braid, coverage nom. 85.6 % 
Sheath 
PVC, approx. 0.45 mm wall thickness, black, UV resistant, flame retardant 
  Outer diameter 2.8 ± 0.13 mm ∅ 
 
 
Electrical properties at 20°C 
 
DC resistance inner conductor 
 
max.Ω/km 
317 
Insulation resistance 
 
min. GΩxkm 
Capacitance at 
   1  kHz 
nom. nF/km 
105 
Nominal velocity of propagation 
 
66 
Impedance 
 
Ω
 
50 ± 2 
 
 
Acc. to MIL 17/119 
Attenuation at 
    1  MHz 
dB/100m 
nom. 3.7 
 
 
    5  MHz 
dB/100m 
nom. 8.5 
 
 
  10  MHz 
dB/100m 
nom. 12 
 
 
  20  MHz 
dB/100m 
nom. 15 
 
 
  50  MHz 
dB/100m 
nom. 19 
     max. 21 
 
100  MHz 
dB/100m 
nom. 30 
     max. 33 
 
200  MHz 
dB/100m 
nom. 45 
     max. 52.5 
 
400  MHz 
dB/100m 
nom. 59 
     max. 82 
 
800  MHz 
dB/100m 
nom. 84 
     max. 128 
 
   1  GHz 
dB/100m 
nom. 92 
 
max. 180.44 
HF voltage, peak value (not for power purposes) 
max.kV  
1.0 
Working voltage (nominal 
voltage) 
50 Hz 
U
eff
    kV 
1.5 
Test voltage 
 
U
eff
    kV 
2.0 
 
 
Mechanical and thermal properties 
 
Weight 
 
approx. kg/km 
12 
Minimum bending radius 
fixed installation 
mm 
15 
 
repeated bendings 
mm 
28 
Permissible temperature range 
fixed installation 
°C  - 40 bis + 80  
 
moved 
°C  - 10 bis + 80 
Fire load 
 
kWh/m 
0.04 
Flame propagation 
flame retardant according to IEC 60332-1-2 
 
RoHS directive 
                This cable confirms to RoHS directive (2002/95/EG)