Hameg HM 8001-2 Mainframe HM 8001-2 24-8001-2000 Data Sheet
Product codes
24-8001-2000
HM8001-2E/090812 · C&E · Subject to change without notice · © HAMEG Instruments GmbH
®
· DQS-certified in accordance with DIN EN ISO 9001:2008, Reg.-No.: 071040 QM08
HAMEG Instruments GmbH · Industriestr. 6 · D-63533 Mainhausen · Tel +49 (0) 6182 8000 · Fax +49 (0) 6182 800100 · www.hameg.com · info@hameg.com
Mainframe HM8001-2
All data valid at 23 °C after 30 minutes warm-up.
General information
Mainframe with power supply accommodates 2 modules
Power supply module
Details of available supply
voltages and load capability:
refer to manual HM8001 (www.hameg.com)
2 x 8 V
ac
max. 0.4 A each
2 x 5 V
dc
max. 1 A each
4 x 20 V
dc
max. 0.5 A each
Voltages between 5 V and 20 V are programmable from each module
(Polarity selectable)
Available output power:
each module max. 25 W
All DC voltages are electronically stabilized,
floating and short-circuit proof. Current
output of 2 HM8040-3 with HM8001-2:
sum of all Channels <2 A
Miscellaneous
Power switch (ON/OFF) located between the two modules on the front
panel.
Safety class:
Safety Class I (EN61010-1)
Power supply:
115/230 V~ (50…60 Hz), CAT II
Max. permissible
line fluctuation
±10 %
Power consumption:
max. 110 W (with overload protection)
Operating temperature:
+5…+40 °C
Storage temperature:
-20…+70 °C
Rel. humidity:
5…80 % (non condensing)
Dimensions (W x H x D):
285 x 75 x 365 mm
Weight:
approx. 4 kg
Accessories supplied: Line cord, Operating manual
Recommended accessories:
HO801 4 BNC connectors
HZ42
Recommended accessories:
HO801 4 BNC connectors
HZ42
19" Rackmount kit 2RU
HZ809 Test Adapter