Hameg 23-7042-0500, 156W 3 Output Variable DC Power Supply, Linear, Bench 23-7042-0500 Data Sheet

Product codes
23-7042-0500
Page of 2
HM7042-5E/150812 · C&E · Subject to change without notice · © HAMEG Instruments GmbH
®
 · DQS-certified in accordance with DIN EN ISO 9001:2008, Reg.-No.: 071040 QM08
HAMEG Instruments GmbH · Industriestr. 6 · D-63533 Mainhausen · Tel +49 (0) 6182 8000 · Fax +49 (0) 6182 800100 · www.hameg.com · info@hameg.com
Triple Power Supply HM7042-5
All data valid at 23 °C after 30 minutes warm-up.
Outputs
2 x 0…32 V/2 A and
0…5.5 V/5A
ON/OFF  pushbutton  control,  SMPS  fol-
lowed by a linear regulator, floating outputs 
for parallel/serial operation, current limit 
and electronic fuse
Channel 1+3 (32 V)
Range:
2 x 0…32V, continuously adjustable 2 knobs 
(coarse / fine)
Ripple:
≤100 µV
rms
 (3 Hz…300 kHz)
Current:
max. 2 A
Current limit/
electronic fuse:
 
0…2 A, continuously adjustable (knob)
Recovery time (10…90 % load variation):
80 µs within ±1 mV of nominal value
30 µs within ±10 mV of nominal value
0 µs within ±100 mV of nominal value
Max. transient deviation typ. 75 mV
Recovery time (50 % basic load, 10 % load variation):
30 µs within ±1 mV of nominal value
5 µs within ±10 mV of nominal value
0 µs within ±100 mV of nominal value
Max. transient deviation typ. 17 mV
Display
7-segment LED
32.00V (4 digit) / 2.000 A (4 digit)
Resolution
0.01 V/1 mA
Display accuracy
±3 digit voltage / ±4 digit current
LED
indicates current limit
Channel 2 (5.5 V)
Range:
0…5.5 V, continuously adjustable (knobs)
Ripple:
≤100 µV
rms
 (3 Hz…300 kHz)
Current:
max. 5 A
Current limit/electronic
fuse:
 
0…5 A, continuously adjustable (knob)
Recovery time (10…90 % load variation):
80 µs within ±1 mV of nominal value
10 µs within ±100 mV of nominal value
Max. transient deviation typ. 170 mV
Recovery time (50 % basic load, 10 % load variation):
30 µs within ±1 mV of nominal value
15 µs within ±10 mV of nominal value
0 µs within ±100 mV of nominal value
Max. transient deviation typ. 60 mV
Display:
7-segment LED
5.50 V (3 digit)/5 A (3 digit)
Resolution
0.01 V/10 mA
Display accuracy
±3 digit voltage/±1 digit current
LED
indicates current limit
Maximum ratings
Max. voltage applicable to output terminals:
CH 1 + CH 3
33 V
CH 2
6 V
Reverse voltage:
max. 0.4 V
Reverse current:
max. 5 A
Voltage to earth:
max. 150 V
Miscellaneous
Safety class:
Safety class I (EN61010-1)
Mains supply:
115/230 V ±10 %; 50…60 Hz, CAT II
Mains Fuse:
115 V: 2 x 5 A slow blow 5 x 20 mm 
230 V: 2 x 2.5 A slow blow 5 x 20 mm
Power consumption:
max. 330 VA/250 W
Operating temperature:
+5…+40 °C
Storage temperature:
-20…+70 °C
Rel. humidity:
5…80 % (non condensing)
Dimensions (W x H x D):
285 x 75 x 365 mm
Weight:
approx. 7.4 kg
Accessories supplied: Operating manual, line cord, CD
Recommended accessories:
HZ10S  5 x silicone test lead (measurement connection in black)
HZ10R  5 x silicone test lead (measurement connection in red)
HZ10B  5 x silicone test lead (measurement connection in blue)
HZ42 
19" Rackmount Kit 2RU