Rigol MSO1074Z-S 4-channel oscilloscope, Digital Storage oscilloscope, MSO1074Z-S User Manual

Product codes
MSO1074Z-S
Page of 172
RIGOL 
2-98 
  DS1000Z Programming Guide 
:TRIGger:PATTern 
 
Command List: 
 
 
:TRIGger:PATTern:PATTern 
Syntax 
:TRIGger:PATTern:PATTern <pattern1>,<pattern2>,<pattern3>,<pattern4> 
:TRIGger:PATTern:PATTern? 
Description 
Set or query the pattern of each channel in pattern trigger.   
Parameter 
Name 
Type 
Range 
Default 
<pattern1> 
Discrete 
{H|L|X|R|F} 
<pattern2> 
Discrete 
{H|L|X|R|F} 
<pattern3> 
Discrete 
{H|L|X|R|F} 
<pattern4> 
Discrete 
{H|L|X|R|F} 
 
Explanation 
  H: set the pattern of the channel selected to “H”, namely the voltage level is higher 
than the threshold level of the channel. 
  L: set the pattern of the channel selected to “L”, namely the voltage level is lower 
than the threshold level of the channel. 
  X: set the pattern of the channel selected to “Don’t Care”, namely this channel is not 
used as a part of the pattern. When all the channels in the pattern are set to “Don’t 
Care”, the oscilloscope will not trigger.
 
  R/F: set the pattern to the rising or falling edge of the channel selected.
 
  You can not to specify patterns of two channels to rising edge or falling edge at the 
same time. If one edge item is currently defined and then another edge item is 
defined in another channel in the pattern, the former edge item defined will be 
replaced by X.
 
  The four parameters from left to right in the command set the pattern of CH1, CH2, 
CH3 and CH4 respectively. 
 
Return 
Format 
The query returns the patterns of all channels.   
Example 
:TRIGger:PATTern:PATTern H,R,L,X