Rigol DS2072A 2-channel oscilloscope, Digital Storage oscilloscope, DS2072A User Manual

Product codes
DS2072A
Page of 284
 
RIGOL 
DS2000A User’s Guide
 
 
5-23  
 
Pattern Trigger   
 
Identify a trigger condition by looking for a specified pattern. This pattern is a logical 
“AND” combination of the two channels. Each channel can have a value of high (H), 
low (L) or don’t care (X). A rising or falling edge can be specified for one channel 
included in the pattern. When an edge is specified, the oscilloscope will trigger at the 
edge specified if the pattern set for the other channel is true (H or L). If no edge is 
specified, the oscilloscope will trigger on the last edge that makes the pattern true. If 
both the channels in the pattern are set to “Don’t Care”, the oscilloscope will not 
trigger.   
H
L
 
Trigger Type: 
Press Type to select “Pattern”. At this point, the trigger setting information as shown 
in the figure below is displayed at the upper right corner of the screen. 
 
 
Channel Selection: 
Press Source to select CH1 or CH2 as the channel source for H, L, X or edge 
condition. The current signal source is displayed at the upper right corner of the 
screen. 
 
Pattern Setting: 
Press Code to set the pattern of the current channel. At this point, the pattern 
setting area (as shown in the figure below) is displayed at the bottom of the screen.   
 
 
: set the pattern of the channel selected to “H”, namely the voltage level is 
higher than the threshold level of the channel.   
 
: set the pattern of the channel selected to “L”, namely the voltage level is 
lower than the threshold level of the channel.   
 
: set the pattern of the channel selected to “Don’t Care”, namely this channel 
is not used as a part of the pattern. When both the channels in the pattern are 
set to “Don’t Care”, the oscilloscope will not trigger.