Phase
- Amount one waveform leads or lags another in 
time expressed in degrees, where 360 degrees comprise one 
waveform cycle. 
 
FRR
- Time between the first rising edge of Source 1 and 
the first rising edge of Source 2. 
 
FRF
- Time between the first rising edge of Source 1 and 
the first falling edge of Source 2. 
 
FFR
- Time between the first falling edge of Source 1 and 
the first rising edge of Source 2. 
 
FFF
- Time between the first falling edge of Source 1 and 
the first falling edge of Source 2. 
 
LRR
- Time between the first rising edge of Source 1 and 
the last rising edge of Source 2. 
 
LRF
- Time between the first rising edge of Source 1 and 
the last falling edge of Source 2. 
 
LFR
- Time between the first falling edge of Source 1 and 
the last rising edge of Source 2. 
 
LFF
- Time between the first falling edge of Source 1 and 
the last falling edge of Source 2. 
All Mea (Measurement) Settings 
Pressing the All Mea option button shows a menu where you can choose 
to display a given set of measurement values for a Source Channel, and 
turn On or Off its corresponding measurement values for Voltage and 