Rigol DS1204B 4-channel oscilloscope, Digital Storage oscilloscope, DS1204B User Manual

Product codes
DS1204B
Page of 164
RIGOL 
©  2008 RIGOL Technologies, Inc. 
User‟s Guide for DS1000B Series 
 
2-45 
 
Figure 2-54      Table 2-32 The Alternative trigger menu   
(Page 1/2 Trigger Type: Video) 
 
Menu 
Settings 
Comments 
Alt 
Channel 
CH1-CH2 
CH1-CH3 
CH1-CH4 
CH2-CH3 
CH2-CH4 
CH3-CH4 
To 
specify 
the 
current 
alternative  trigger  channels  as 
any two channels selected form 
CH1, CH2, CH3, CH4. 
select 
CH1, CH2,   
CH3, CH4 
To  select  vertical  channel 
among CH1, CH2, CH3, CH4 in 
alternative  trigger  mode  so  as 
to configure further settings. 
Type 
Edge trigger 
Pulse trigger 
Video trigger 
To  select  trigger  type  for 
current channel. 
 
Figure 2-55      Table 2-33 The Alternative trigger menu   
(Page 2/2 Trigger Mode: Video) 
 
Menu 
Settings 
Comments 
Polarity 
  Normal polarity 
 
Inverted polarity 
 
Trigger on negative going 
sync pulses. 
Trigger on positive going sync 
pulses. 
Sync 
ALL lines 
Line Num 
Trigger on all lines. 
Trigger on a specified line. 
Odd field 
Even field 
Select to trigger on odd field 
or even field. 
Standard 
PAL/SECM 
NTSC
 
Select Video standard. 
Set Up 
 
To  go  to  set  up  menu,  see 
Table 2-36.