Ziehl MINIPAN 300 AC Digital panel-mounted measuring device MINIPAN 300 AC 1 mV - 500 V/AC / 1 mA - 1 A Assembly dimensi D 440320.CO Data Sheet

Product codes
D 440320.CO
Page of 2
ZIEHL industrie-elektronik GmbH + Co KG, Daimlerstr. 13, D-74523 Schwäb. Hall, Tel.: +49 791 504-0, www.ziehl.com
3.1.
3
3
MINIPAN 300
Electrical Data
Power supply
Mechanical Data
MINIPAN 300
Accuracy
rated supply-voltage Us
tolerance DC
tolerance AC
power consumption
frequency
(do always connect 1 input only)
DC-Meter
measuring-range / resistance of
input / overload capacity
AC-Meter
measuring-range / resistance of
input / overload capacity
Temperature Pt 100 (RTD)
sensor-input
resistance 3-wire
measuring time AC/DC
measuring time Pt 100
resolution
error (of full measuring range)
DC-voltage, DC-current
AC-voltage, AC current
temperature factor
total error at temperature-
measuring
temperature factor
housing
dimensions (h x w x d) mm
terminals
Attachment
protection housing/
protection terminals
weight
AC/DC 24-240 V
DC 20 - 297 V (0,85 x 24 V...1,35 x 220 V)
AC 20 - 264 V (0,85 x 24 V...1,1 x 240 V)
< 3 VA
48...62 Hz
potentially separated from supply-voltage
±
 300 mV / 120 k
Ω
 / max. 
±
2,5 V
±
 10.00 V / 1 M
Ω
 / max. 
±
50 V
+ 500.0 V / -199.9 V / 3 M
Ω
 / max. 
±
600 V
+ 100.0 V / -100.0 V / 3 M
Ω
 / max. 
±
600 V
+ 20.00 mA / -19.99 mA/ Shunt 15 
Ω
/ max. 
±
100 mA
±
 1.00 A / Shunt 150 m
Ω
 / max. 
±
2 A
150 mV / 900 
Ω
 / max. 2,5 V
10.00 V / 100 k
Ω
 / max. 50 V
50.0 V / 1 M
Ω
 / max. 60 V
500.0 V / 3 M
Ω
 / max. 600 V
1.00 A / Shunt 150 m
Ω
 / max. 2 A
- 199,9 ... + 850,0 
°
C (= -328 ... +1563 
°
F)
Pt 100, 2- or 3-wire connection
max. 3 x 50 
Ω
<400 ms
<400 ms
+9999 / -1999
±
 0,1 % 
±
 1 Digit
±
 0,5 % 
±
 1 Digit
±
 0,02 % / K
±
 0,3 % of value 
±
 0,5 K
±
 0,03 
°
C / K
Measuring inputs
panel-mount housing
36 x 72 x 79 mm
8-pole
panel-mount, panel cutout 33
 +0,6
 x 68
 +0,6
 mm
max. thickness of panel 8 mm
IP 30
IP 20
ca. 120 g
Order Notice
Programming ex works:
If you want us to deliver the devices readily programmed ex works (extra charge), please
specify in your order the following parameters (see also operating manual):
Measuring Input
Mesuring Range
Display Range
Number of fixed zeros at the end
Delay of Display
Code-lock
bold = compulsory
e.g. 100 V
e.g. 20...80 V, no specification = measuring input
e.g.. 0...500,0 (do not forget the decimal point)
0, 1 oder 2
e.g. 1 s
yes/no