Lecroy WaveStation 2022 Function Generator, Frequency Generator WaveStation 2022 User Manual

Product codes
WaveStation 2022
Page of 32
WaveStation SCPI Command Reference Manual 
 
13 
 
920595 RevA 
BTWV 
– Burst Wave Command 
DESCRIPTION 
Sets the waveform type to a Burst waveform or sets specific Burst waveform parameters. 
Note: The carrier waveform cannot be set to Noise when using a Burst waveform set to NCycle. 
COMMAND
 
SYNTAX 
<channel>: BursTWaVe <parameter> 
<channel>:= {C1,C2} 
<parameter>:= {A parameter from  the following table.} 
Parameters 
Value 
Description 
STATE 
<state> 
Sets the instrument to a Burst waveform type or retrieves Burst waveform 
parameters. 
PRD 
<period> 
This parameter sets the period of the waveform and is only applicable when 
the trigger source is INT, yet not applicable when the carrier waveform is a 
Noise or gated Burst waveform. 
STPS 
<start phase>  Not applicable to Noise or Pulse carrier waveforms, this parameter sets the 
Burst waveform’s start phase value. 
GATE_NCYC 
<gate ncycle>  Not applicable to Noise carrier waveforms, this parameter allows you to 
configure the Burst waveform as either Gated or NCycle. 
TRSR 
<trigger> 
Only applicable to a Burst carrier waveform with NCycle selected, this 
parameter sets the Burst waveform trigger source. 
DLAY 
<delay> 
Only applicable to a Burst carrier waveform with NCycle selected, this 
parameter sets a Burst waveform’s delay value. 
PLRT 
<polarity> 
Only applicable for gated Burst carrier waveforms, this parameter sets the 
basic waveform’s polarity value. 
TRMD 
<trig mode> 
Only applicable to a Burst carrier waveform with NCycle selected, this 
parameter sets the trigger mode (INT, EXT, MAN) value.  
EDGE 
<edge> 
Only applicable to a Burst carrier waveform with NCycle selected, this 
parameter sets a Burst waveform’s trigger mode (slope; positive, negative, or 
OFF) value. 
TIME 
<cycle time> 
Only applicable to a Burst carrier waveform with NCycle selected, this 
parameter sets a Burst waveform’s cycle time value. 
MTRIG 
 
Only applicable to a Burst carrier waveform, with NCycle selected, and the 
trigger source set to MAN, this parameter manually triggers the WaveStation. 
CARR, WVTP 
<wave type> 
Sets the carrier waveform type value. 
CARR, FRQ 
<frequency> 
Sets the carrier waveform frequency value. 
CARR, AMP 
<amplifier> 
Sets the carrier waveform amplification value. 
CARR, OFST 
<offset> 
Sets the carrier waveform offset value. 
CARR, SYM 
<symmetry> 
Sets the carrier waveform symmetry value. 
CARR, DUTY 
<duty> 
Only applying to Square carrier waveforms, this parameter sets the duty cycle 
value.  
CARR, PHSE 
<phase> 
Sets the carrier waveform phase value. 
CARR, DLY 
<carrier 
delay> 
Only applicable when the carrier waveform is set to Pulse, this parameter sets 
the delay value. 
CARR, VAR 
<variance> 
Only applicable when the carrier waveform is set to Noise, this parameter sets 
the variance.