920595 RevA
BTWV
– Burst Wave Command
DESCRIPTION
Sets the waveform type to a Burst waveform or sets specific Burst waveform parameters.
Note: The carrier waveform cannot be set to Noise when using a Burst waveform set to NCycle.
COMMAND
SYNTAX
<channel>: BursTWaVe <parameter>
<channel>:= {C1,C2}
<parameter>:= {A parameter from the following table.}
Parameters
Value
Description
STATE
<state>
Sets the instrument to a Burst waveform type or retrieves Burst waveform
parameters.
parameters.
PRD
<period>
This parameter sets the period of the waveform and is only applicable when
the trigger source is INT, yet not applicable when the carrier waveform is a
Noise or gated Burst waveform.
the trigger source is INT, yet not applicable when the carrier waveform is a
Noise or gated Burst waveform.
STPS
<start phase> Not applicable to Noise or Pulse carrier waveforms, this parameter sets the
Burst waveform’s start phase value.
GATE_NCYC
<gate ncycle> Not applicable to Noise carrier waveforms, this parameter allows you to
configure the Burst waveform as either Gated or NCycle.
TRSR
<trigger>
Only applicable to a Burst carrier waveform with NCycle selected, this
parameter sets the Burst waveform trigger source.
parameter sets the Burst waveform trigger source.
DLAY
<delay>
Only applicable to a Burst carrier waveform with NCycle selected, this
parameter sets a Burst waveform’s delay value.
parameter sets a Burst waveform’s delay value.
PLRT
<polarity>
Only applicable for gated Burst carrier waveforms, this parameter sets the
basic waveform’s polarity value.
basic waveform’s polarity value.
TRMD
<trig mode>
Only applicable to a Burst carrier waveform with NCycle selected, this
parameter sets the trigger mode (INT, EXT, MAN) value.
parameter sets the trigger mode (INT, EXT, MAN) value.
EDGE
<edge>
Only applicable to a Burst carrier waveform with NCycle selected, this
parameter sets a Burst waveform’s trigger mode (slope; positive, negative, or
OFF) value.
parameter sets a Burst waveform’s trigger mode (slope; positive, negative, or
OFF) value.
TIME
<cycle time>
Only applicable to a Burst carrier waveform with NCycle selected, this
parameter sets a Burst waveform’s cycle time value.
parameter sets a Burst waveform’s cycle time value.
MTRIG
Only applicable to a Burst carrier waveform, with NCycle selected, and the
trigger source set to MAN, this parameter manually triggers the WaveStation.
trigger source set to MAN, this parameter manually triggers the WaveStation.
CARR, WVTP
<wave type>
Sets the carrier waveform type value.
CARR, FRQ
<frequency>
Sets the carrier waveform frequency value.
CARR, AMP
<amplifier>
Sets the carrier waveform amplification value.
CARR, OFST
<offset>
Sets the carrier waveform offset value.
CARR, SYM
<symmetry>
Sets the carrier waveform symmetry value.
CARR, DUTY
<duty>
Only applying to Square carrier waveforms, this parameter sets the duty cycle
value.
value.
CARR, PHSE
<phase>
Sets the carrier waveform phase value.
CARR, DLY
<carrier
delay>
delay>
Only applicable when the carrier waveform is set to Pulse, this parameter sets
the delay value.
the delay value.
CARR, VAR
<variance>
Only applicable when the carrier waveform is set to Noise, this parameter sets
the variance.
the variance.