To Edit Waveforms 
 
Users can edit the waveforms which have been already saved. Press Edit to enter 
the waveform editing interface. 
 
1.  Interpolation 
Press Interp to turn the interpolation between the defined waveform points on or 
off. 
  ON: the waveform editor will connect the two points with a straight line. 
  OFF: the waveform editor will hold a constant voltage level between two 
points and create a step waveform. 
 
2.  Zoom 
Press Zoom to turn the zoom function on or off. 
  ON: only displays the current point in the middle of the waveform editor 
window. 
  OFF: displays all the initial points in the waveform editor window. 
 
3.  Current point 
Press CurPoint and use 
  to set the desired points currently edited and the 
range available is from 1 to the initial points. 
Method one: 
Rotate 
  directly to set the desired points currently edited. 
Method two: 
Press 
  to input desired paramrter values and unist directly using the pop-up 
numeric keyboard. 
 
4.  Voltage   
Press Voltage to set the voltage value of the current point and the range 
available is from -2.5 V to +2.5 V. 
Method one: 
Rotate 
  directly to set the desired voltage value. 
Method two: 
Press 
  to input desired paramrter values and unist directly using the pop-up 
numeric keyboard.