MENU: press this key to open the trigger operation menu. This oscilloscope 
provides various trigger types. 
 
FORCE: press this key to generate a trigger signal forcefully. 
 
 
CLEAR 
 
 
Press this key to clear all the waveforms on the screen. If the 
oscilloscope is in “RUN” state, new waveforms will still be displayed. 
 
 
RUN/STOP 
 
 
Press this key to set the state of the oscilloscope to “RUN” or 
“STOP”.   
In “RUN” state, the key is illuminated in yellow. 
In “STOP” state, the key is illuminated in red. 
 
 
SINGLE 
 
 
Press this key to set the trigger mode to “Single”. In single trigger 
mode, press FORCE to generate a trigger signal immediately.   
 
 
AUTO 
 
 
Press this key to enable the waveform auto setting function. The 
oscilloscope will automatically adjust the vertical scale, horizontal 
time base and trigger mode according to the input signal to realize 
optimum waveform display. Note that auto setting requires that the 
frequency of the signal under test should be no lower than 50 Hz, 
the duty cycle be greater than 1% and the amplitude be at least 20